Before installing the actuator, check that the moving parts of the window on which it is to be installed are in perfect working
condition and that they open and close properly and are well balanced (where applicable).
Check that the electrica
l supply used corresponds to the indications on the “TECHNICAL DATA” label attached to the
machine and that the given temperature range is compatible with the place of installation.
Actuator specifications must be sufficient for movement of the window without encountering any obstacle. The limits
indicated in the technical data table must not be superseded
(page 19)
and the most appropriate stroke should be selected.
Calculations should be checked using the formula indicated on page 18.
Ensure that the actuator has not been damaged during transport, first visually and then by powering in both directions.
Check that the width of the inside of the window (where the actuator is to be assembled) is over 405 mm, otherwise the
actuator should not be installed.
Check that once the actuator has been installed the distance between the fixed part of the window frame (where the
actuator is to be assembled) and the mobile part of the window frame (where the bracket is to be fixed) is greater than
or equal to 0 mm. If this is not the case the actuator will not function correctly as the window will not close correctly. If
required, add additional thickness below the support brackets to reset the quota.
14.1. Preparation of actuator for assembly
Before starting assembly of the actuator, prepare the following material for completion, equipment and tools.
◆
For fixing onto metal window frames: M5 threaded inserts
(6 pieces)
, M5x12 flat headed metric screws
(6 pieces)
.
◆
For fixing onto wooden window frames: self-threading screws for wood Ø4.5
(6 pieces)
.
◆
For fixing onto PVC window frames: self-threading screws for metal Ø4.8
(6 pieces)
.
◆
Equipment and tools: measuring tape, pencil, drill/screwdriver, set of drill heads for metal, insert for screwing in, electricians
pliers, screwdrivers.
14.2. Assembly with outward opening window.
Outward application Figure 2 Figure 3
Figure 4 Figure 5 Figure 6
Above the drawing of specific application using accessories provided. For different mountings, please contact
manufacturer.
A.
Pencil in an “X” over the centre line of the window frame (
Fig. 2
).
B.
Select the correct form of brackets (
Fig. 3
).
C.
Attach the template to the window frame
(fixed part)
and line axis up with the centre line “X” traced earlier
(Fig. 4)
.
Warning
:
for window frames not on the same plane, cut the part of the template coloured in grey and fix this to the moveable part of the
window frame, taking care to keep it in the same position.
D.
Bore holes in the window frame at the points indicated on the template
(Fig. 5)
.
E.
Assemble the two brackets with the distancer
(to help position correctly. Once it has served its purpose it can be removed)
.
Mount the supports onto the frame with the appropriate screws provided. Check that everything is aligned both horizontally
and vertically.
F.
Mount the bracket for outward opening windows onto the moveable part of the frame in accordance with the markings
indicated on the template.
G.
Complete assembly of the chain terminal with the safety clip inserted onto the pin Ø4x32
(provided)
in median position
(see
fig. 6)
.
H.
Mount the actuator onto the brackets by inserting the two openings at each side onto the corresponding pins on the brackets.
I.
Rotate the actuator 90°, bring the chain terminal up to the bracket and insert the pin into the opening on the bracket. Insert the
safety clip into the bracket.
J.
Check that the exit on the chain is perfectly aligned with the bracket. If the chain is not aligned with the bracket, loosen the
fixing screws and reposition the bracket correctly.
K.
Check all electrical connections with the diagram on the label attached to the lead and and in conformity to indications on
chapter 9
– Electrical connection.
L.
Carry out a complete check of opening and closure of the window. Once the closure phase has been completed, check that
the window frame is completely closed by checking the pressure on the weather strips.