6. Label data and markings
The VARIA SLIM RADIO actuators have CE marking and comply with the Standards listed in the Declaration of Conformity. They
also come with a Declaration of Incorporation, due to their classification by the Machinery Directive as “partly completed
machines”. Both declarations are included in the final pages of this manual.
The plate data is displayed on an adhesive label placed on the outside of the casing, which must remain intact and visible.
The main information it displays includes: manufacturer's address, product name - model number, technical characteristics,
production date and serial number.
In the event of a complaint, please indicate the serial number (SN) displayed on the label. An explanation of the symbols used on
the label to abbreviate the technical characteristics is given in the table in the chapter on
“TECHNICAL DATA”.
7. Electric power supply
Warning. Check that the electric power supply used corresponds to that specified on the “technical data” label
attached to the machine.
The manufacturer cannot be held liable for damage due to an application which is incorrect or non-compliant with regulatory
requirements.
The actuator is powered by a mains voltage, in alternating current, of 110-230V~ with a frequency of 50/60 Hz.
The actuator is already equipped with a power supply cable which is 2 meters long. The cable has two colored conductors:
Phase (brown) and Neutral (sky-blue).
The connection between the line and the power supply cable of the actuator must be protected by a magnetothermic switch
between the line and actuator.
7.1. Selecting the cross-section of electric power supply cables
The cross-section of the electric power supply conductors must comply with current standards on electrical systems, without
prejudice to standard EN 60335 for connected electrical devices.
8. Electric power supply and sensor connection
8.1. Electric power supply cable
The power supply cable is already wired to the actuator. It is used for the electric power supply of the system and should be
connected to the electricity mains. The power supply cable has two conductors: sky-blue, brown.
8.2. Cable entry to the terminal block
The cables entering on the left, in the same cable feedthrough, are the following low-
voltage cables:
•
Rain sensor cable
(five conductors for the SPR sensor, two for SPR RADIO)
.
•
Manual open/close control cable.
After the wiring is completed
(see t
he “Electrical connection” chapter)
and the cables and
cable feedthrough are arranged properly, it is recommended that the cable entry be sealed
with a drop of silicone; this will prevent humidity or water from entering.
9. Electrical connection
E
LECTRIC SHOCK HAZARD
.
Before beginning any work on the machine's wiring, make certain that the electric power has been disconnected;
failure to observe this rule may compromise safety.
Cable entry to the terminal block
•
No connection to the symbols indicated to the side.
FUNCTION NOT PRESENT in this system
•
Connection of the rain detection sensor. Two different rain sensor models can be connected:
-
Model
SPR
with five conductors:
▪
Red (+) connected to
+15V
,
▪
Black (-) connected to
-15V
,
▪
Blue (N.O. contact) connecte
d to “
PIOGGIA
”,
▪
Green (common) connected to
-15V
,
▪
Violet (N.C. contact) not used and should be electrically isolated.
-
Model
SPR RADIO
with two conductors:
▪
Red (+) connected to
+15V
,
▪
Black (-) connected to
-15V
,