F4 PLUS
16
UK
9 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
DIP
Status
Function
Description
DIP
Status
Function
8 - DIP SWITCH DIP1
DIP 5
1_
Disables the limit switch input
Enables the limit switch input
ON
OFF
MOTOR 1 CLOSING
LIMIT SWITCH
DIP 6
1_
Disables the limit switch input
Enables the limit switch input
ON
OFF
MOTOR 2 OPENING
LIMIT SWITCH
DIP 7
1_
Disables the limit switch input
Enables the limit switch input
ON
OFF
MOTOR 2 CLOSING
LIMIT SWITCH
DIP 8
1_
Disables the limit switch input
Enables the limit switch input
ON
OFF
PHOTOCELL
DIP 9
1_
The outputs 7-8 of the terminal board are used to control a FLASHLIGHT equipped
with its own flashing circuit.
ON
TERMINALS 7-8
FUNCTIONING
OFF
The outputs 7-8 of the terminal board are used to control a COURTESY LIGHT
that remains active for 2 minutes after the motor movement. In this mode,
the terminals 28-29 can be used to connect a FLASHLIGHT without a flashing
circuit.
DIP 10
1_
For HYDRAULIC motors only.
If the gate has not performed any operation in the last 5 hours, a 2-second closing
pulse is given.
ON
HYDRAULIC
LOCK
RETENTION
OFF
HYDRAULIC RETENTION deactivated.
DIP2_1
The STOP input (23) functions as 8K2 FRAME and when intercepted, will
invert the motion for 2 seconds in order to free the obstacle.
The active contact indication LED will be D23 (the LED D10 will not be
considered).
ON
OFF
TERMINAL 23
FUNCTIONING
The STOP input (23) functions as N.C. STOP and when intercepted, will lock
the motion.
The active contact indication LED will be D10 (the LED D23 will not be
considered).
In the case of a system with only one motor
and using the limit switches, the DIP
switches 4, 5, 6 and 7 are to be set to OFF;
while if using only one type of limit switch
(e.g. FCAM1 and/or FCCM1), enable only
the corresponding DIP switch (set to OFF).
DIP 4
1_
Disables the limit switch input
Enables the limit switch input
ON
OFF
MOTOR 1 OPENING
LIMIT SWITCH
DIP2_2
Terminal M4 operates as WARNING LIGHT.
ON
OFF
TERMINAL M4
FUNCTIONING
Terminal M4 operates as FLASHING LIGHT.