F4 PLUS
UK
14
5A
FAST
Protects the circuit board and the accessories.
160mA
FAST
F1
F2
Description
Position
Value
Type
6 - PROTECTION FUSES
Protects the circuit board and the motors.
7- WARNING LEDs
Always on. Goes off when the CLOSING LIMIT SWITCH of motor 2 is
reached.
FCCM2
Always on. Goes off when the OPENING LIMIT SWITCH of motor 2 is
reached.
FCAM2
Always on. Goes off when the CLOSING LIMIT SWITCH of motor 1 is
reached.
FCCM1
Always on. Goes off when the OPENING LIMIT SWITCH of motor 1 is
reached.
FCAM1
Always on. Goes off when the photocell is intercepted interrupting the
beam.
PHOTO
Comes on when the START command is activated and goes off when
released.
START
Always on. Goes off when the STOP button is activated (open)
(see DIP2_1).
STOP
Comes on when the PEDESTRIAN start command is activated and goes off
when released.
PED
Comes on when the 8K2 FRAME is activated (see DIP2_1).
SAF. 8K2
Description
Signal
Colour
LED
L8
GREEN
L6
L5
L7
L4
L3
L2
RED
L1
YELLOW
L10
RED
RED
RED
RED
RED
GREEN