22
DPT260
UK
7.6 - SLAVE TERMINAL CONNECTIONS
Terminal Contact
1-2-3
26-27-28
25
4
5
24
6-7-8
9-10
15
16
13
17
11-12
14
67-68-69
18-19-20
22-23
N.C.
N.O.
LED
Connected device
Through terminals 26-27-28. Protected by F5 fuse
Through terminals 1-2-3. Protected by F5 fuse
Inlet for earthing
Earthing for hydraulic pump motor
None
None
Outlet 230V power supply for hydraulic pump (common terminal 8)
L7
L3
L4
L1
L2
Outlet 24V power supply for solenoid valve
Outlet 24V power supply for acoustic buzzer
Outlet 24V power supply for flashing light
Common: Limit switch - Acoustic buzzer - Flashing light
Common: Lower limit switch - Acoustic buzzer - Flashing light
Inlet for pressure switch or upper limit switch
Inlet for lower limit switch
CAN-BUS connection slave circuits (67= CANH - 68= CANL - 69= 0V)
Inlet 24V power supply from transformer
Inlet 230V power supply