GiBiDi DPT260 Fitting, Operation And Maintenance Instructions Download Page 14

14

DPT260

5.6 - LAYING OF INDUCTIVE LOOPS

If  the  system  is  set  on  automatic  mode  (bollards  rise  only  after  the  occurred  transit  of  a  vehicle)  it  is 
necessary to install inductive loops to detect metallic masses (vehicles).

Inductive loops are suitable for two different applications:

• “Limited” protection of the bollards 

(PIC. 12 - PIC. 13)

. In this case a single inductive loop is installed around the 

bollards, it avoids the raising in case a vehicle is over the bollards or in the immediate surroundings.

• “Extended” protection of the bollards 

(PIC.14)

. In this case two inductive loops are installed, one before and one 

beyond the bollards; a vehicle in motion is detected about 3m before the bollards and the detection is enabled up 
to 3m beyond the bollards. This function let the system detect in advance any other vehicle in transit and avoid any 
eventual accident.

Notes on the installation:

1. 

Standard inductive loops are 9,60m long (usually m 1,80 x 3,00); therefore it is possible to take into account other 
dimensions.

2. 

The inductive loop is made of a special cable of 9mm diameter and it is suitable for the direct laying into the 
ground, without any sheath nor protection.

3.

  It is essential to check the presence of electro-welded meshes into the ground. If this is the case, you shall remove 

the mesh for about 25cm beyond the perimeter of the inductive loops 

(PIC. 16

).

4. 

Inductive loops shall be laid with “rounded corners” 

(PIC. 16 - PIC. 17)

.

5. 

Inductive loops shall be laid approx. 7cm under walking level. In presence of cobblestones or similar, of 10mm 
thickness or greater, it is necessary to flatten out that material in order to allow the laying of the loops at the 
suggested depth. As an alternative, it is possible to lay the inductive loop between one cobble and onother like a 
“Greek fret”.

6. 

Inductive loops are supplied with a junction box 

(PIC. 15)

 which is connected to to the control unit through a line for 

signal transmission. This line is made of a special insensitive cable which has a standard length of 15m (it is 
possible to purchase lines of greater lengths).

7. 

Inductive loops can also detect an outbound vehicle and therefore carry out the automatic lowering of the bollards.

UK

Summary of Contents for DPT260

Page 1: ...DPT260 DPT260 UK Automatic bollards FITTING OPERATION AND MAINTENANCE INSTRUCTIONS...

Page 2: ...ed anti flame cable The dimension of the main power supply line must be evaluated by the installeraccordingtothequantityofbollards 500Weachbollard andthedistancefromtheoutputplace inorderto grantaprop...

Page 3: ...g effects in a range between 25 C and 55 C and foradeterminedtime lessthan24hours at 70 C The bollards do not require any availability of spare parts Gi Bi Di S r l warehouse can send any spare parts...

Page 4: ...s Lowering speed 25 cm s Manual emergency lowering Standard optional automatic lowering if power failed Safety reversal pressure switch Standard Connection line to control unit Standard 10 m max lengh...

Page 5: ...4 BOLLARD COMPONENTS 40 600 275 940 560 560 SOLENOID VALVE RISING SIDEBLOCK LOWER LIMIT SWITCH LOWER SUPPORT BASE REFLECTING STRIP FLASHING LIGHT HEAD MOVING CYLINDER FRAME PASSIVE BOX PISTON HYDRAULI...

Page 6: ...6 DPT260 5 INSTALLATION PROCEDURE 190 mm 200 mm 300 mm 1200 mm 1000 mm 1000 mm Quota di calpestio 10 mm SENSO DI TRAFFICO TRAFFIC WAY 50 mm PIC 1 PIC 2 PIC 3 PIC 5 PIC 4 UK...

Page 7: ...7 DPT260 5 INSTALLATION PROCEDURE UK PIC 6 FOUNDATION BRACKET CONTROL UNIT JUNCTION BOX 400 x 400 mm FLEXIBLE SHEATH diameter 50 mm max 1600 mm max 1600 mm...

Page 8: ...S WALKING LEVEL ROAD SURFACE ADDITIONAL CONCRETE CASTING SUPPORTING SLAB M8 CHEMICAL ANCHORS M16 CHEMICAL ANCHORS WATERPROOF PIT IN STAINLESS STEEL WATERPROOFING SHEATH 10 mm 50 mm 600 mm 275 mm 450 m...

Page 9: ...9 DPT260 PIC 8 PIC 10 PIC 11 PIC 9 M16 M16 5 INSTALLATION PROCEDURE UK...

Page 10: ...10 DPT260 5 INSTALLATION PROCEDURE min 25 cm 95 cm 95 cm 95 cm 95 cm 3 00 m 1 80 m 280 cm 200 cm 80 cm 80 cm 5 5 cm 9 cm 15 cm 15 cm 15 cm PIC 12 PIC 14 PIC 16 PIC 13 PIC 15 PIC 17 Control Unit UK...

Page 11: ...annel complete with covering grid to avoid rainwater infilitrations in the pits due to incline An important factor in the installation of bollards prior to the assessment of the permeability of soil i...

Page 12: ...it to the control unit for the electrical connection of the bollards PIC 2and4 WARNING If the distance between pits and control unit is more than 10m purchase the bollards equipped withelectricalconne...

Page 13: ...e the stainless steel waterproof pits to the ceilingofthebasement 7 Laythepipesfortheelectricalcablesfromthebollardstothecontrolunit 8 Laythepipesforrainwaterdrainagefromthewaterproofpitstothedrainage...

Page 14: ...ke into account other dimensions 2 The inductive loop is made of a special cable of 9mm diameter and it is suitable for the direct laying into the ground withoutanysheathnorprotection 3 Itisessentialt...

Page 15: ...G No 1 2 3 4 5 6 Colour BLUE GREY YELLOW BLACK WHITE RED Device FLASHING LIGHT BUZZER optional SOLENOID VALVE FOR LOWERING SAFETY PRESSURE SWITCH LIMIT SWITCH BOLLARD DOWN LIMIT SWITCH BOLLARD UP opti...

Page 16: ...ting bollard downposition Grey Sensor for detecting bollard up position nc Red Solenoid valve 24Vdc 1 3 2 4 2 4 2 4 4 2 1 1 2 4 2 6 BROWN 5 WHITE 3 YELLOW 1 BLUE 2 GREY Hydraulicl unit 4 BLACK M12 1 3...

Page 17: ...5bollards i e controlunitfor8bollards Electronic circuit Standard housing for control unit Protection class Power supply Control unit protection Service transformer Permitted ambient temperature Relat...

Page 18: ...everysinglebollard 5 Layandconnectanyadditionallines e g push buttonpanel inductiveloops trafficlights etc 6 Before running a functional test consult the instructions related to the electric connectio...

Page 19: ...parameters of the system 230V 10 per each moving bollard Master Slave F1 F2 F3 F5 F1 F6 F7 F2 Typology Protection 2A delayed Protection transformer 230V 24 VAC supply 1A delayed Protection timer progr...

Page 20: ...t outlet for yearly weekly progremmer connection Outlet 230V power supply for hydraulic pump common terminal 8 L7 L3 L4 L1 L2 L13 L13 LIN L5 L12 L11 L14 Outlet 24V power supply for solenoid valve Outl...

Page 21: ...Step Step Outlet for hydraulic pump power supply rising Outlet for hydraulic pump power supply lowering Outlet for hydraulic pump power supply in motion Inlet for safety devices Rising phase disabled...

Page 22: ...ne None Outlet 230V power supply for hydraulic pump common terminal 8 L7 L3 L4 L1 L2 Outlet 24V power supply for solenoid valve Outlet 24V power supply for acoustic buzzer Outlet 24V power supply for...

Page 23: ...ts rising lowering Power supply enabled Power supply enabled Limit switch enabled device in low position gate open Outlet enabled fixed or flashing depending on setting Outlet enabled fixed or flashin...

Page 24: ...STEPFUNCTION The bollard after the first control from up position moves to down position after another control the bollardreturnstoupposition step stepfunction CONTROLSENABLED Controlsfortheoperationo...

Page 25: ...pressed until the completeloweringofthebollard 4 Fastenthedowel PIC 23andPIC 24 PIC 25 PIC 26 PRESSURE SWITCHAS RISING LIMIT SWITCH ENABLED At the final stage of the rising the pressure switch worksas...

Page 26: ...a bollard during the rising phase the safety pressure switch detects the presence of a weight and immediately interrupts the rising phase and makes the bollards lower to down position inversion contr...

Page 27: ...upt the rising phase and make bollardsgobacktodownposition inversioncontrolbyinductiveloop Wetherthissituationoccurs beforecrossingit isnecessarytowaitforthegreensectortoturn If a pedestrian steps on...

Page 28: ...levant during winter they can be equipped with an heating resistance which prevents ice formation between the cylinder and the fixed side crown allowingfortheproperoperationofthesystem If automatic bo...

Page 29: ...icted or blocked In order to keep an adeguate drainage use a drill machine of suitable length approx 15mm anddrillinthe4holes drivingthetipintothegravelbelowforabout10cm Inthiswayanydepositthatobstruc...

Page 30: ...is rising and the pressure switch detects a pressure increase usually caused by the detection of a weight corresponding to 40 kg or more on the bollard e g a person the bollard stops and goes back to...

Page 31: ...and transmitters check the correct operation from a distance of about 30m and as far as possible verify the wear of thetransmittersandthebuilt inbatteries Check visually the overall status of the cont...

Page 32: ...ghthesuitablespyhole Unfasten and remove the black cap of the hydraulic pump generally placed abovethetransparentspyhole andfillitwiththesameoiluptoabouthalfofthe spyhole ATTENTION USEORIGINALOILONLY...

Page 33: ...ed thisblackwirepowersthefirstpointat 24VDC Move the black wire from the first terminal to the second or the third one to poweranotherlightpoint Test the proper operation of the multiled flashing ligh...

Page 34: ...ocedurebelow Bollardoutofthepit Bollardindownposition turn230Vpowersupplyoff Extract the waterproof protection made of black soft rubber for about 5cm toreachtheadjustingscrew Unscrew and remove the n...

Page 35: ...of 45 and after each step command a rising movement Once the bollard is completely up check the pressure on the pressure gauge and most important hear that the hydarulic unit continues running for abo...

Page 36: ...orreplaced For the pressure switch adjustment please consult the chapter10 SPECIFICOPERATIONS Note generally only the pressure switches of old supply are adjustable and recognizable from a waterproof...

Page 37: ...n reversalfunctionbypressureswitchenabled If it is possible adjust the pressure switch sensibility adjustable old version or replace the pressure switch pre adjusted and hermetic new version to increa...

Page 38: ...n it is lower than a certain value it performs an automatic adjustment When it occurs this problemmaybecausedby The automatic pressure adjust ment has been accidentally excluded The safety inductive d...

Page 39: ...board Consult the chapter 10 SPECIFICOPERATIONS UK EC Declaration of conformity The manufacturer GI BI DI Via Abetone Brennero 177 B 46025 Poggio Rusco MN ITALY declares that the products AUTOMATIC B...

Page 40: ...DI S r l Via Abetone Brennero 177 B 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 w w w g i b i d i c o m Cod AIC0061 01 2020 Re...

Reviews: