7.4 - MASTER TERMINAL CONNECTIONS
Terminal Contact
1-2-3
31-32-33
46-47-48
51-52
34-39
40-41-42
43-44-45
49-50
4
5
53
54
55-59
6-7-8
9-10
15
16
28-30
29-30
13
17
11-12
14
24-25
26-27
60-61
62-63
64-65
65-66
67-68-69
20-21
22-23
N.C.
N.O.
N.O.
N.O.
N.O.
N.C.
N.O.
N.O.
N.C.
LED
Connected device
Through terminals 31-32-33. Protected by F5 fuse
Through terminals 1-2-3. Protected by F5 fuse
Outlet for traffic light signal (neutral exchange)
Inlet for 230V power supply
Inlet/outlet for transformer connection
Outlet 230V
(40= red - 41= green - 42= common)
for traffic light connection
Outlet 230V for traffic light connection (40= red - 41= green - 42= common)
Inlet for breaking glass button - emergency automatic lowering
(only for GiBiDi devices equipped with automatic lowering - NO 230V)
Earthing for hydraulic pump motor
None
None
Inlet for earthing
Inlet/outlet for yearly/weekly progremmer connection
Outlet 230V power supply for hydraulic pump (common terminal 8)
L7
L3
L4
L1
L2
L13
L13
LIN
L5
L12
L11
L14
Outlet 24V power supply for solenoid valve
Outlet 24V power supply for acoustic buzzer
Outlet 24V power supply for flashing light
Outlet 24V power supply for radio receiver
Outlet 12V power supply for radio receiver
Common: Limit switch - Acoustic buzzer - Flashing light
Common: Limit switch - Acoustic buzzer - Flashing light
Inlet for pressure switch or upper limit switch
Inlet for lower limit switch
Start control inlet (lowering control or step-step)
Inlet control from radio receiver (lowering control or step-step)
Inlet for future functions or customizations
Outlet for future functions or customizations
Inlet for lowering control (common terminal 65)
Inlet for rising control (common terminal 65)
CAN-BUS connection slave circuits (67= CANH - 68= CANL - 69= 0V)
Inlet for safety devices (example: inductive loops detector)
Outlet 24V power supply for safety devices (example: inductive loops detector)