18
DPT260
UK
6.5 - EXAMPLE OF CONTROL UNIT
TRANFORMER
100VA 230V 0-24V
AUTOMATIC SWITCH
1P + N 6kA C216A
UNIPOLAR EARTHING
TERMINAL BOARD -
2
16 mm
METALLIC BOX
IP66 - mm 600 x 500 x 200
MASTER CIRCUIT
SLAVE CIRCUITS
EXAMPLE OF CONTROL UNIT FOR 3 GI.BI.DI. DPT260 BOLLARDS
1.
Lay the wall box.
2. Lay and connect the 230V main power supply line.*
3. Lay and connect the earthing line.
4. Lay and connect the electric connection lines to every single bollard.
5. Lay and connect any additional lines, e.g.: push-button panel - inductive loops - traffic lights - etc .
6. Before running a functional test consult the instructions related to the electric connections provided with the
system.
* The main power supply line of the control unit must be directly connected to the main switch set inside the control
unit. The dimension of the main power supply line must be evaluated by the installer according to the quantity of
bollards (500W each bollard) and the distance from the output place, in order to grant a proper supply
(230V +/-10% per each moving bollard).
6.6 - CONTROL UNIT WIRING
PIC. 20