AUTOMATIC CLOSING
1
2
3
4
Disables the automatic closing
If the pedestrian opening is activated, the PEDESTRIAN key will
cause the closing.
If the total opening is activated, the START will cause the closing and
the PEDESTRIAN key will be uninfluential.
Enables total automatic closing H9
Enables pedestrian automatic closing H11
PEDESTRIAN key uninfluential when in pause
Enables
only
total automatic closing H9
If the pedestrian opening is acticated, the PEDESTRIAN key
determines the closing
Enables
only
pedestrian automatic closing H11
PEDESTRIAN key uninfluential when in pause
A
C
F H E
ESC
-
OK
+
When the display shows the main menus (letters A C F H E or just
some of them depending on which password has been used to access
programming) let the letter C blink by moving to the right or to the left
with the b or –
Once the letter C blinks confirm with the OK button.
MENU C: FUNCTION SELECTION
A3
A3
A3
A3
STEP BY STEP WITH STOP
LOGIC
STEP BY STEP LOGIC
AUTOMATIC / CONDOMINIUM
LOGIC
DEAD MAN LOGIC
2
3
4
5
It enables the STEP BY STEP WITH STOP logic
Operation:
START
open
Next START
stop
Next START
close
Next START
open
If automatic closing has been activated (menu A5) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate.
“START” closes the gate.
PEDESTRIAN is uninfluential in opening. It will be active in stand-by
if the pedestrian automatic closing is disabled. In closing, it opens
both leaves.
®
®
®
®
It enables the STEP BY STEP logic
:
If automatic closing has been activated (menu A5) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate.
If the door is open, “START” closes the gate.
PEDESTRIAN is uninfluential in opening. It is active in stand-by if the
pedestrian automatic closing is disabled. In closing, it opens both
leaves.
Operation
START
®
open
Next START
®
close
Next START
®
open
It enables the AUTOMATIC/CONDOMINIUM logic
Operation:
START
®
open
Next START(s)
®
uninfluential if the system is opening, or it re-
charges the pause time (if the gate is in pause) and the automatic
closing is activated.
After pause time:
- If the automatic closing is activated, the system closes automatically.
- If the automatic closing is not activated, a START or a PEDESTRIAN
command close the gate (if the opening is pedestrian).
PEDESTRIAN is uninfluential in opening. It is active in stand-by if the
pedestrian automatic closing is disabled. In closing, it opens both
leaves.
It activates the DEAD MAN logic
Operation:
START
opens only if the START key is held down.
PEDESTRIAN
closes only if the PEDESTRIAN key is held down.
In Dead Man's mode the keys on the control unit assume the following
meanings:
START (+ key)
open
PEDESTRIAN (- key)
close
The opening and closing movements in the dead man's mode stop
on the first limit switch it meets. Deceleration is never activated.
The only possible regulations are: PHASE SHIFT IN OPENING –
PHASE SHIFT IN CLOSING – MOTOR POWER 1 AND 2 –
AMPEROMETRIC LEVEL during MOTOR POWER 1 and 2.
If the keys are continuously held down, the flashing light remains
active even if the motors stopped on the limit switches.
Two motors always working.
®
®
®
®
Example Programming
MENU C
By means of + or – buttons you can select the submenus (C1, C2, C3,..)
The digits on the lcd are fixed to show that is no possible any
modification.
The button ESC lets you to go to the upper level (menus A, C, F, H E).
With OK button you enter the selected menu and the digits start blinking
to show that is now possible to modify the values and the ESC button
becomes irrelevant.
Right now with + e – buttons you can change the settings of the
selected menu.
With the OK button you confirm the data and return to the selected
menu with fixed digits.
ESC
-
OK
+
C 1 1
Right now with + and – buttons you can scroll the other submenus of
the menu C and you can follow the same procedure shown above.
The ESC button lets you to go to the upper level (menus A, C, F, H, E)
ESC
-
OK
+
C 2 2