44
UK
45
UK
BA24
BA24
Description
MENU C
Menu
Function
Status Description
C1
C2
C5
C7
C8
C9
C10
C12
C10
C11
C6
C3
C4
FAST CLOSING
FLASHING LIGHT
DECELERATIONS
PHOTOCELL 1
PHOTOCELL 2
SAFETY EDGE
HAMMER STROKE
ADDITIONAL TIME T3
IN OPENING AND CLOSING
HAMMER STROKE
FINAL STROKE IN
OPENING AND CLOSING
ANTI-CRUSHING /
LIMIT SWITCH
AMPEROMETRIC
PREFLASHING
LIMIT SWITCH
1
2
1
1
1
1
1
1
2
3
2
2
2
2
3
1
2
3
2
2
3
3
1
1
2
2
3
1
3
2
It disables the fast closing function
Blinking flashing light output
Disables the final stroke in opening and closing
Additional time T3 disabled
Disables the deceleration function
Photocell 1 disabled
Photocell 2 disabled
Safety edge disabled
Enables fast closing function.
Operation:
Active only on photocell 1.
Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells
Fixed flashing light output
Enables the deceleration function
Photocell 1 enabled
Photocell 2 enabled
Safety edge with 8K2 in series resistor enabled
Safety edge with N.C. contact enabled
Disables the hammer stroke function
Enables the hammer stroke in closing to allow the electrical lock
release.
Operation:
when the START command is given, the sequence is:
- electrical lock activation
- closing motion
1 s
- opening
- after
2 s
electronic lock release
Not activated with the sliding configuration.
We suggest to not use the “Hammer stroke” function with electro-
mechanical operators.
Enables the hammer stroke function both in opening and closing to
allow the electric lock release.
Operation:
When the START command is given, the sequence is:
- electric lock activation
- pulse in closing / opening of
1 s
- opening / closing
- after
2 s
electric lock release
Not active with sliding configuration
We suggest to not use the “Hammer stroke” function with electro-
mechanical operators.
Enables the final stroke in closing
Operation:
At the end of the closing time without decelerations, a pulse of 3 s
is given with the power set up in F2 and F6 menus, followed by
another pulse of 2 s with the power set up in F1 and F5 menus.
When the decelerations are active, the final stroke is given at the end
of the deceleration period.
The end stroke is controlled by the amperometric level, adjusted in
F4 and F8 menus during the first 3 s and in F3 and F7 menus in the
following 2 s.
The end stroke is not controlled by safety devices.
Not active with sliding configuration and dead man logic.
Enables the “Additional time T3” function in closing
:
Sets up T3 as the time set up for the deceleration with the same force
setting of F2 and F6 menus
Operation
Enables the “Additional time T3” function in opening and closing
:
Sets up T3 as the time set up for the deceleration with the same force
setting of F2 and F6 menus
Operation
Enables the final stroke in opening and closing
Operation:
At the end of the opening and closing time without decelerations,
a pulse of 3 s is given with the power set up in F2 and F6 menus,
followed by another pulse of 2 s with the power set up in F1 and
F5 menus.
When the decelerations are active, the final stroke is given at the end
of the deceleration period.
The end stroke is controlled by the amperometric level, adjusted in
F4 and F8 menus during the first 3 s and in F3 and F7 menus in the
following 2 s.
The end stroke is not controlled by safety devices.
Not active with sliding configuration and dead man logic.
Disables the limit switch reading
Disables pre-flashing.
The flashlight and the motors START at the same time.
Enables the single reading of the limit switch. See paragraph
“LIMIT SWITCHES AND AMPEROMETRIC OPERATION”
Enables 3-second pre-flashing before motor START.
Enables the double reading of the limit switch. See paragraph
“LIMIT SWITCHES AND AMPEROMETRIC OPERATION”
ANTI-CRUSHING / LIMIT SWITCH AMPEROMETRIC function not
enabled
Enables the LIMIT SWITCH AMPEROMETRIC function
Amperometric stops the motion
Enables the ANTI-CRUSHING function
Amperometric inverts the motion
WARNING:
ENABLE THE ANTI-CRUSHING ONLY IF ALSO THE
LIMIT SWITCHES ARE ENABLED