38
UK
39
UK
BA24
BA24
PASSWORD MANAGEMENT
You can enter the control board programming menu in 2 different ways, using 2 different password depending on
which menu you want to set.
When prompted for the password enter 0000.
In such a way you enter only the menus listed below:
A3
Operation logic
A5
Automatic closing
H9
Pause time
E94
Firmware release
CHECK ENABLED INPUT
During stand by (closed barrier) the control unit perform a test to verify the consistency between the enabling of
an input by the menu and the status of the relevant contact
WARNING:
The display indication is not a verification of the correct functionality of the input but simply a check on what is
enabled by the menu and the input status.
If the menu related to one input is disabled there will not be any check and the display indication will be
the one shown in the “Closed contact” column.
When prompted for the password enter the default one 1234 .
In such a way you enter all the menus.
WARNING:
If you change the password in the menu E92, that is if you change the default password 1234 with another one,
then you can no more access the system by entering 0000. The only way to do that is by resetting the control
board or by entering again the password 1234 in the menu E92.
BASIC MODE
ADVANCED MODE
ENTERING PASSWORD PROCEDURE
P A S S
ESC
-
OK
+
After 3 s appears P A S S on the display.
Press the OK button to continue with the procedure.
Press and hold the ESC key for 3 s to exit and return to previous point.
The message E X I T will appear on the display.
0
0 0 0
ESC
-
OK
+
It appears on the display 4 digits ( 0 0 0 0 ) with the former of them
flashing.
If you want to enter the ADVANCED programming, by means of
+ or – keys type the first digit of the installer code set in the menu E92.
Once you get to the desired digit confirm with the OK button and go to
the next step.
If you want to enter the BASIC programming, confirm the digit 0
WARNING !
At first use of the control board the default PASSWORD set in the
menu E92 is: 1 2 3 4
Change the value of menu E92 only after having completed the
settings of the menus A C F H E.
0
0
0 0
ESC
-
OK
+
The second digit blinks.
If you want to enter the ADVANCED programming, by means
of + or – keys type the second digit of the installer code set in the
menu E92.
Once you get to the desired digit confirm with the OK button and go to
the next step.
If you want to enter the BASIC programming, confirm the digit 0
The ESC button will move the flashing digit to the left until the first digit.
Press ESC and OK button simultaneously for 3 s.
At the same time will appear M E N U on the display.
ESC
-
OK
+
M E N U
Signal
PHOTOCELL 1
PHOTOCELL 2
SAFETY EDGE
LIMIT SWITCH
STOP
Open contact
Closed contact
S
_
L
_
C
_
F
_
F
_
Summary of Contents for BA24