50
UK
UK
51
UK
BA24
BA24
Right now with + and – buttons you can scroll the other submenus of
the menu E and you can follow the same procedure shown above.
The ESC button lets you to go to the upper level (menus A, C, F, H, E).
E 1 1
ESC
-
OK
+
By means of + or – buttons you can select the submenus (E1, E3, E5,..)
The digits on the lcd are fixed to show that is no possible any
modification.
The button ESC lets you to go to the upper level (menus A, C, F, H E).
With OK button you enter the selected menu and the digits start blinking
to show that is now possible to modify the values and the ESC button
becomes irrelevant.
Right now with + e – buttons you can change the settings of the selected
menu.
With the OK button you confirm the data and return to the selected menu
with fixed digits.
E 90
ESC
-
OK
+
The digits on the lcd are still fixed to show that is not possible any
modification.
The b and – are irrelevant
The ESC button return to the upper level
With OK button you enter the selected menu and the digits begin
blinking.
By means of + or – buttons you can select the submenus (E90, E92, …)
The digits on the lcd are fixed to show that is no possible any
modification.
The button ESC lets you to go to the upper level (menus A, C, F, H, E).
With OK button you enter the selected menu and the value set is shown.
0 0
0
5
ESC
-
OK
+
0 0 0
5
ESC
-
OK
+
E 90
ESC
-
OK
+
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
With OK you confirm and go to the next step.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
Appears again menu E90.
With ESC return to the upper level (menu A, C, F, H, E)
Menu
Function
Status
1
Description
Disables the photocell 1 test
Enables the photocell 1 test.
The photocell 1 transmitter must be connected to the clamps 14 and
17.
Operation:
When the START or the PEDESTRIAN command is given,
the power to safety devices is taken off for 0,5 sec. and then restored:
if the photocell 1 input opens and immediately goes back to N.C. the
motors START, otherwise a fault will be signalled by 4 blinks (1 sec.)
of the flashing light.
ESC
-
OK
+
A C F H
E
ESC
-
OK
+
A C F H
E
When the display shows the main menus (letters A C F H E or just
some of them depending on which password has been used to access
programming) let the letter E blink by moving to the right or to the left
with the b or –
Once the letter E blinks confirm with the OK button.
When the display shows the main menus (letters A C F H E or just
some of them depending on which password has been used to access
programming) let the letter E blink by moving to the right or to the left
with the b or –
Once the letter E blinks confirm with the OK button.
from E1 to E89
from E90
MENU E: ENABLING AND DISABLING
The menu E contains submenus with different programming mode.
Menus from E1 to E89 have the same programming mode as menu C;
menus identified by E90 onwards have the same programming mode of menu F.
Example Programming
MENU E
Example Programming
MENU E
ESC
-
OK
+
E 3 2
0 0 0 5
ESC
-
OK
+
0
0
0 5
ESC
-
OK
+
A digit of the lcd blinks (depending on the menu the blinking digit could
be different).
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
Description
MENU E
E1
PHOTOCELL 1 TEST
2
Summary of Contents for BA24