BA230
42
UK
A2
A3
STEP BY STEP
WITH STOP LOGIC
STEP BY STEP
LOGIC
AUTOMATIC /
CONDOMINIUM
LOGIC
3
2
3
4
It configures the system for two motors.
In the menu E7 it will be possible to set the courtesy light output:
1 = courtesy light disabled
2 = courtesy light disabled
3 = courtesy light on ELECTRIC LOCK 2 output
The courtesy light output is 3-minutes timed.
It enables the STEP BY STEP WITH STOP logic
Operation
:
START
→
open
Next START
→
stop
Next START
→
close
Next START
→
open
If automatic closing has been activated (menu A5) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate. “START”
closes the gate
PEDESTRIAN is uninfluential in opening. It will be active in stand-by
if the pedestrian automatic closing is disabled. In closing, it opens both
leaves.
It enables the STEP BY STEP logic
Operation
:
START
→
open
Next START
→
close
Next START
→
open
If automatic closing has been activated (menu A5) and the opening
phase is at the end of the cycle, when the pause time has elapsed
(menu H9), the control unit automatically closes the gate.
If the door is open, “START” closes the gate
PEDESTRIAN is uninfluential in opening. It is active in stand-by if the
pedestrian automatic closing is disabled. In closing, it opens both
leaves.
It enables the AUTOMATIC/CONDOMINIUM logic
Operation
:
START
→
o
pen
Next START(s)
→
u
ninfluential if the system is opening, or it zeroes
the pause time (if the gate is in pause) and the automatic closing is
activated.
If the automatic closing is activated, the system closes automatically.
If the automatic closing is not activated, a “START” or a pedestrian
command close the gate (if the opening is pedestrian).
PEDESTRIAN is uninfluential in opening. It is active in stand-by if the
pedestrian automatic closing is disabled. In closing, it opens both
leaves.
NUMBER OF MOTORS