BA230
51
UK
0 0
0
5
0 0 0
5
E 90
ESC
ESC
ESC
-
-
-
OK
OK
OK
+
+
+
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
Appears again menu E90.
With ESC return to the upper level (menu A, C, F, H, E)
Menu
E1
E3
Function
PHOTOCELL 1 TEST
SAFETY DEVICE TEST
Status
1
1
2
2
Description
Disables the photocell 1 test
Disables the safety devices test.
Enables the photocell 1 test
The photocell 1 transmitter must be connected to the clamps 16 and 19.
Operation
:
When the START or the PEDESTRIAN command is given, the power
to safety devices is taken off for 0,5 and then restored: if the photocell
1 input opens and immediately goes back to NC the motors START,
otherwise a fault will be signalled by 4 blinks (1 sec.) of the flashing
light.
Enables the safety devices test
Operation
:
PHASE 1
: when the Start or the Pedestrian command is given, the
electronic circuit is tested: relay, triac, etc.
If an anomaly is detected, it will be indicated by 4 long flashes (2 sec.)
of the flashing light. The test must be performed when the motors are
connected.
If the control unit is set for one motor, the test will be performed only
for motor 1 circuit.
WARNING
: During the test, the motors will be activated in opening and
closing for about 300 msec.
DUE TO THE MOTION, THE DOOR MAY CRASH AGAINST THE
MECHANICAL STOPS. CHECK THE SYSTEM SAFETY/INTEGRITY
AFTER THIS PHASE.
The exclusion of SAFETY DEVICE (menu C9-1) excludes the safety
edge test.
Description
MENU E
Summary of Contents for AS05581
Page 59: ...BA230 59 NOTE ...