• SAFETY DEVICE choice with N.C. contact or 8K2 resistive.
• Specific menu for the exclusion of the accessories not used (photocell 1, photocell 2 and safety devices).
• Possibility to program: automatic closing, fast closing, pre-flashing, hammer stroke, final closing and opening
stroke, courtesy light, ending movement additional time, flashing light (both flashing and fixed), external clock
management with three different modes, number of cycles for scheduled maintenance, installer code, number
of performed cycles and power supply days
INSTALLATION
INSTALLATION WARNINGS
Use cable glands that can assure the correct mechanical connection of the wiring and maintain the IP55
protection degree of the box (2).
• Before proceeding with the installation, fit a magnetothermal or differential switch with a maximum capacity of
10A upstream of the system. The switch must guarantee omnipolar separation of the contacts, with an opening
distance of at least 3 mm.
• To prevent possible interference, differentiate and always keep the power cables (minimum cross-section
1,5mm²) separate from the signal cables (minimum cross-section 0,5mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that must be connected to the same N.C. (normally closed) input, and in
parallel all the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of
the product may compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always check carefully the proper functioning of the system and the devices used.
• This instruction manual addresses people qualified for the installation of “live equipment”. Therefore, good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
• Mark the automated gate with visible warning plates.
• Warn the user that children and animals may not play or stand around near the gate.
• Appropriately protect the dangerous points (for example, use a sensitive frame).
• The control board alone will not ensure safety again crushing. Make sure that the safety devices connected to
the control board are appropriate for the purpose.