BA230
45
UK
C10
C11
HAMMER STROKE
FINAL STROKE
1
1
2
2
3
3
Disables the hammer stroke function
Disables the final stroke in opening and closing.
Enables the hammer stroke function to help the release of the
electric lock/s in OPENING
Operation
:
After the Start command, the sequence is:
- Electrical locks enabling
- 1 s pulse in closing
- opening
- After 2 s, electrical locks release
Disabled with sliding configuration
We suggest not to use the “Hammer stroke” function with
electromechanical operators.
Enables the final stroke in closing
Operation
:
At the end of the closing time without deceleration, a pulse of 2 s is
given at full power.
With active decelerations is given at the end of the deceleration period.
The final stroke is not controlled by safety devices.
Not active with sliding configuration and with dead man logic
Enables the hammer stroke function to help the electrical lock/s
release in OPENING and CLOSING
Operation
:
After the Start command, the sequence is:
-Electrical locks enabling
-Motor pulse in the electrical lock freeing direction
-Motion direction in the required direction
-After 2 s, electrical locks release
Disabled with sliding configuration
We suggest not to use the “Hammer stroke” function with
electromechanical operators.
Enables the final stroke in opening and closing
Operation
:
At the end of the opening or closing time without decelerations, a pulse
of 2 s is given at full power.
With active decelerations is given at the end of the deceleration period.
The final stroke is not controlled by safety devices.
Not active with sliding configuration and with dead man logic
C12
C13
ADDITIONAL TIME T3
IN OPENING AND CLOSING
HYDRAULIC
BLOCK MAINTENANCE
1
1
2
3
T3 excluded
Disables the hydraulic block maintenance
Sets T3 as the time set for the deceleration with the same setting of
menus F1 and F5. The type of functioning is C5-2
Sets T3 as the time set for the deceleration with the same setting of
menus F2 and F6. The type of functioning is C5-2
Summary of Contents for AS05581