HD50
- 33 -
V1.5
Address
Type
Input Register description
6006 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
2-wire Pt1000
sensor of
channel
N
: 0=°C, 1=°F.
6008 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
3-wire Pt1000
sensor of
channel
N
: 0=°C, 1=°F.
6010 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
4-wire Pt1000
sensor of
channel
N
: 0=°C, 1=°F.
6012 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
TC_K
sensor of channel
N
:
0=°C, 1=°F.
6014 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
TC_J
sensor of channel
N
:
0=°C, 1=°F.
6016 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
TC_T
sensor of channel
N
:
0=°C, 1=°F.
6018 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
TC_N
sensor of channel
N
:
0=°C, 1=°F.
6026 +
200 x (
N
-1)
W
Unit of measurement for
TEMPERATURE
with
TC_E
sensor of channel
N
:
0=°C, 1=°F.
6036 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped 0…1 V input: see the table of indexes
6037 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped 0…1 V input:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
6038 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped 0…50 mV: see the table of indexes
6039 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped 0…50 mV:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
6040 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped 4…20 mA input: see the table of indexes
6041 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped 4…20 mA input:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
6042 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped potentiometric input: see the table of indexes
6043 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped potentiometric input:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
6046 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped 0…10 V input: see the table of indexes
6047 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped 0…10 V input:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
6052 +
200 x (
N
-1)
W
Measurement unit of the quantity associated to channel
N
if the channel is
configured as mapped -50…50 mV: see the table of indexes
6053 +
200 x (
N
-1)
SW
Resolution of the quantity associated to channel
N
if the channel is config-
ured as mapped -50…50 mV:
…, -2=100, -1=10, 0=1, 1=0.1, 2=0.01, …
Summary of Contents for Delta OHM HD50 Series
Page 51: ......