HD50
- 31 -
V1.5
Address
Type
Input Register description
1010 +
200 x (
N
-1)
SW
T
EMPERATURE
with 4-wire
Pt1000 sensor
of channel
N
in the set meas-
urement unit (x10).
1011 +
200 x (
N
-1)
B
Alarm for temperature with 4-wire Pt1000 sensor
of channel
N
: 0=OFF,
1=lower threshold alarm, 2=higher threshold alarm.
1012 +
200 x (
N
-1)
SW
T
EMPERATURE
with
TC_K
sensor of channel
N
in the set measurement
unit (x10).
1013 +
200 x (
N
-1)
B
Alarm for temperature with TC_K sensor
of channel
N
:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1014 +
200 x (
N
-1)
SW
T
EMPERATURE
with
TC_J
sensor
of channel
N
in the set measurement unit
(x10).
1015 +
200 x (
N
-1)
B
Alarm for temperature with TC_J sensor
of channel
N
:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1016 +
200 x (
N
-1)
SW
T
EMPERATURE
WITH
TC_T
sensor
of channel
N
in the set measurement unit
(x10).
1017 +
200 x (
N
-1)
B
Alarm for temperature with TC_T sensor
of channel
N
:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1018 +
200 x (
N
-1)
SW
T
EMPERATURE
with
TC_N
sensor
of channel
N
in the set measurement unit
(x10).
1019 +
200 x (
N
-1)
B
Alarm for temperature with TC_N sensor
of channel
N
:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1026 +
200 x (
N
-1)
SW
T
EMPERATURE
with
TC_E
sensor
of channel
N
in the set measurement unit
(x10).
1027 +
200 x (
N
-1)
B
Alarm for temperature with TC_E sensor
of channel
N
:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1028 +
200 x (
N
-1)
SW
Input value in
mV
of channel
N
(x10). Only if channel
N
is configured as
0…1 V
input.
1029 +
200 x (
N
-1)
B
Alarm for channel
N
if the channel is configured as 0…1 V input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1030 +
200 x (
N
-1)
SW
Input value in
mV
of channel
N
(x100). Only if channel
N
is configured
as
0…50 mV
input.
1031 +
200 x (
N
-1)
B
Alarm for channel
N
if the channel is configured as
0…50 mV input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1032 +
200 x (
N
-1)
SW
Input value in
mA
of channel
N
(x100). Only if channel
N
is configured
as
4…20 mA input.
1033 +
200 x (
N
-1)
B
Alarm for channel
N
if the channel is configured as
4…20 mA input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1034 +
200 x (
N
-1)
SW
Position of
potentiometer
in % of channel
N
. Only if channel
N
is config-
ured as
potentiometric input.
1035 +
200 x (
N
-1)
B
Alarm for channel
N
if the channel is configured as
potentiometric input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1036 +
200 x (
N
-1)
SW
Value of quantity associated to channel
N
if the channel is configured as
mapped 0…1 V input.
1037 +
200 x (
N
-1)
B
Alarm for quantity associated to channel
N
if the channel is configured as
mapped 0…1 V input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1038 +
200 x (
N
-1)
SW
Value of quantity associated to channel
N
if the channel is configured as
mapped 0…50 mV input.
1039 +
200 x (
N
-1)
B
Alarm for quantity associated to channel
N
if the channel is configured as
mapped 0…50 mV input:
0=OFF, 1=lower threshold alarm, 2=higher threshold alarm.
1040 +
200 x (
N
-1)
SW
Value of quantity associated to channel
N
if the channel is configured as
mapped 4…20 mA input.
Summary of Contents for Delta OHM HD50 Series