4
Signet 2580 FlowtraMag Meter
The 2580 requires a minimum of 3x ID upstream and 2 x ID downstream of the sensor for best performance.
Sensor Location
Sensor Dimensions
2 in.
Union ends and union nuts shown
3 x I.D.
2 x I.D.
2 x
90° Elbow
3 x I.D.
2 x I.D.
90° Elbow
3 x I.D.
2 x I.D.
2 x 90° Elbow
3 dimensions
Pump/Valve
3 x I.D.
2 x I.D.
Reducer
3 x I.D.
2 x I.D.
1 in.
Union ends and union nuts shown
99.0 mm
(3.90 in.)
276.86 mm
(10.90 in.)
± 1/8 in.
327.7 mm
(12.90 in.)
99.0 mm
(3.90 in.)
239.26 mm
(9.42 in.)
± 1/16 in.
249.4 mm
(9.82in.)
141.2 mm
(5.56 in.)
141.2 mm
(5.56 in.)
99.0 mm
(3.90 in.)
Pipe
1 in.
ID
Pipe
2 in.
ID
Pipe
4 in.
ID
249.4 mm
(9.82 in.)
31.8 mm
(1.25 in.)
7.1 mm
(0.28 in.) x 2
28.7 mm
(1.13 in.)
x 2
35.8 mm
(1.41 in.)
199.64 mm
(7.86 in.)
± 1/16 in.
8.42 ± 0.10 in
Pipe cutout dimension
38.1 mm
(1.50 in.)
38.4 mm
(1.51 in.)
x 2
41 mm
(1.65 in.)
10.18 ± 0.10 in
Pipe cutout dimension
9.7 mm
(0.38 in.) x 2
4 in.
Flange bolt kits and gaskets not shown
(Sold separately)