20
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each bio-
dynamic reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2
Standard and under operating conditions much more severe than those normally found.
1. GENERAL CHARACTERISTICS
Operating pressure
bar (psi)
155 (2248)
Oil supply
l / min
1,28
Oil reservoir capacity
cm
3
960
Degree of protection
IP 20
Dimensions
Ref. to Fig. 8 page 4
Weight with battery
kg
5,6
Motor
V
18
Operating temperature
°C
-15 a +50
Recommended oil
PANOLIN P 9632/1
Safety
maximum pressure valve
Acoustic noise
(1)
dB
L
pA
66,8 (A) L
pCPeak
88 (C) L
WA
82,8 (A)
Vibrations
(2)
m/s
2
0,318
Rechargeable battery
type
CB1840L Li-Ion
V / Ah (Wh)
18 / 4.0 (72)
Weight
g
660
Battery charger
type ASC30-36-EU ASC30-36-USA/CAN
Input
V / Hz (W)
220 - 240 / 50 - 60 (85) 115 /60 (85)
Weight
g
530
ENGLISH
BHP15-18-GF
BHP15-18A-GF