IQ lock AUT, EL / EL DL, EM / EM DL, C / C DL, M / M DL
23
Installation
DIP switch (back of PCB)
à
The DIP switch (1) can be used to switch the terminating resistor for RS485 on and off.
à
If there are more than two bus participants, the resistance must be switched on in the first and last device.
43
ON
OFF
22 x1
21
20
52
31
41
42
2
1
X4
1
Fitting IQ AUT
X
Insert the rod drive IQ AUT (1) into the recess.
X
Make sure that the adapter rod (3) is inserted com-
pletely into the funnel.
The adapter rod (3) must be completely flush to the end
stop so that the hexagon socket screw (2) can be fixed
through the elongated hole.
X
Tighten the hexagon socket screw (2) in the funnel through the front elongated hole.