Configuration program – wide-range reader GCLR 2000
GCLR-I 2000/GCLR-O 2000
22
5.2.2 Sub-menus in the area "Managing the transponder list"
Key disable/output disable
The sub-menu key disable/output disable can be found in the "Managing
the transponder list" area:
In the key disable/output disable sub-menu, the programming buttons
GR.1 and GR.2 can be individually released or disabled. The functions teach
transponder, delete (individual) can be specified separately for group 1 and
group 2 in any combination.
Control field
Explanation
"Delete complete memory" (both push
buttons)
Deletes the memories of the programming
buttons GR.1 and GR.2
Higher-order disabling function for all
outputs via OPTO-IN 3
Deactivates and resets all outputs if input
OPTO-IN3 is active.
Effects:
à
In the event of a fire it is still possible
to close all doors or prevent further
activation.
à
The function of the wide-range reader
can be deactivated at certain times if
passage by transponder is no longer to
be permitted.
The following menu fields are relevant:
à
IN-Field filter
à
Write TAG ID
à
LF transmission setting