Installation and commissioning.
GCLR-I 2000/GCLR-O 2000
8
4.1.3 Checking the LF scanned field
à
Using the field tester:
The LF scanned field can be checked using the field tester.
Flashing LEDs indicate the field coverage.
à
Using the transponder with 2 keys:
The transponder with 2 keys displays the scanned field through a red
LED.
à
Using the LEDs on the housing (optional):
When a transponder has been taught, the green LED flashes as soon as
the transponder is within the scanned field. If a transponder has not been
taught, the green LED goes out as long as the transponder is within the
scanned field.
4.1.4 Cable routing
X
Heed the wiring diagrams and installation instructions of the respective
products.
à
The power supply NT is not required when the voltage supply to the
GCLR is via the drive.
X
Heed the overall current consumption.