"Networked operation" mode of operation
GCLR-I 2000/GCLR-O 2000
26
When the wide-range reader is used as a networked variant, the transmit-
ters (GCLR ID TAG) are programmed via the web interface of the GCMU 524
(refer also to the GCMU 524 manual).
The most important settings are the "System" settings as well as the "Pass/
PIN configuration"
System settings
X
In the main menu of the web interface GCMU 524, open the sub-menu
"System" (1).
1
2
3
4
X
Set pass type (2).
Pass type
Description
Teratron
The ID No. is shown as a decimal figure. There is no
evaluation of the keys for drop-shaped transmitters.
Teratron with key
evaluation
The ID No. is shown as an 11-digit decimal figure. If
one of the keys is pressed, this is shown by a "1" or "2"
as the first digit of the ID No., depending on which key
has been activated. The key has a range of approx. 50
m (wireless).
Teratron with key and
field evaluation
As Teratron with key evaluation, except that the push
button only works if the transmitter with keys is within
the scanned field of the wide-range reader.
X
In the selection menu "Standard reader for a new Door Unit" (3), set
"RS485 reader with HADP protocol".
X
Set "Pass number" in the selection menu "Test mode" (4).