- IN CASE OF ALALRM.
- Press the “ON/OFF” button to disarm the system.
- Press the “PANIC” button to stop the alarm cycle without disarming (only with GT888).
- ALARMS CHECK CONTROL AND ANOMALIES.
LAST ALARM CAUSE:
If during the armed state an alarm has been detected (4 indicators flashes and 4 beeps
to the disarming) or there is anomaly it is possible to check the cause.
When the alarm is disarmed switch the ignition key on and check the LED flash as
indicated in the ALARMS SIGNAL TABLE and ANOMALIES SIGNALS TABLE.
ANOMALIES SIGNALLING:
- Vehicle low battery signalling:
when disarming with the handset, if the vehicle battery is
at 11,6V doesn’t activate the indicators and after the normal acoustic signalling emits 5
anomaly beeps.
- Door open signalling when arming:
the system emits a long beep and a long indicators
flash.
Handset low battery signalling:
when the system is disarmed switch on the vehicle
ignition key athe system emits some flashes of colour GREEN and RED without pauses
(See TABLE ANOMALIES SIGNALLING).
ALARMS SIGNALLINGS TABLE
Check LED
Flashes No.
Input which has
generated the alarm
RED
PAUSE
1
ADDITIONAL MODULES
INPUT
RED
PAUSE
4
DOORS PIN SWITCHES
RED
PAUSE
5
BOOT/BONNET PIN
SWITCH
RED
PAUSE
6
VEHICLE IGNITION KEY
RED
PAUSE
7
WIRES CUT
(only for GT915/916)
ANOMALIES SIGNALLINGS TABLE
Check LED
Flashes No.
Input which has
triggered the alarm
RED / GREEN
HANDSETS BATTERY
COLOUR
N
N = Flashes No.
COLOUR = Flashes colour
LEGEND:
Flashes without pause
RED/GREEN
- The signals sequence of occurred alarms and anomalies detected is repeated at
each vehicle ignition key switching on.
- The alarms system memory is deleted to the following the alarm system arming.
- When the anomaly is solved, the memory is automatically deleted.