2.8.
Configuration of production priorities
Priorities
1.
Allows the response to the different services to be prioritized. Services with the same
priority level can be dealt with simultaneously.
2.9.
Activation of special programs
Floor drying
1.
Used to enable the floor drying program. This program helps control the mortar drying
process using underfloor heating.
2.
It allows setting a schedule with up to six time periods with different outlet
temperatures.
Note:
After all the stages set in the floor drying program are completed, the heat pump
returns to normal operation. If there are requests for the enabled services, the heat pump
deals with them.
Installation bleeding
1.
Used to enable the bleeding program of the installation. This program turns the
circulation pumps of the installation on and off to assist the bleeding.
2.10.
Configuration e-Manager
Grid meter
Used to select the address of the meter in the communication network and the type of
installation: single-phase (1 phase) or three-phase (3 phases).
NOTE:
The default meter address is 100. If you change the meter address on the display,
you must also change it physically on the meter as per the manufacturer's instructions in
the manual.
Installer menu
2/7
a.Change language
b.Configuration
c.Information
Configuration
3/7
b.Sources
c.Services setup
d.Auxiliary systems
Services setup
5/6
d.Pool
e.Priorities
f.Special programs
Priorities
0/ 0/ 0/ 0
000
Installer menu
2/7
a.Change language
b.Configuration
c.Information
Configuration
3/7
b.Sources
c.Services setup
d.Auxiliary systems
Services setup
6/6
d.Pool
e.Priorities
f.Special programs
Drying floor
Enable:
Active phase: 1
h
ºC
h
ºC
1. 12 35.0
2. 12 35.0
3. 12 35.0
4. 12 35.0
5. 12 35.0
6. 12 35.0
Installation purge
Enable:
Time left:130s
Devices turned on
PLEASE WAIT
Installer menu
2/7
a.Change language
b.Configuration
c.Information
Configuration
4/8
c.Services setup
d.e-Manager
e.Auxiliary systems
Grid meter
Enable:
Address:
100
Connection type:
1ph