PROGRAMMING Menu
Date/Time
This is used to adjust the day of the week, date (DD/MM/YY) and time (HH:MM 24-hour
format) of the controller.
Daily saving time
The settings of automatic time change between seasons (autumn-winter / spring-summer)
can be adjusted.
Heat pump schedule
This allows programming up to 4 time periods for each day of the week to switch the heat
pump on / off.
Holiday calendar
This can be used to program up to 3 periods a year when the heat pump stays on or off.
Night-time
This is used to set up a daily time period when the maximum speed of the compressor or
unit heater is limited. This function is especially useful to reduce noise emissions at night.
DHW Schedule / Heating Schedule / Cooling Schedule / Pool Schedule / BC Schedule
This allows programming up to 4 time periods for each day of the week.
Independent time schedules can be set up for DHW, HEATING, COOLING AND POOL
services.
Holiday calendar
This can be used to program up to 3 periods a year when the heat pump stays on or off.
User menu
2/8
On/Off
Programming
Heating
Programming
1/4
a.Date/time
b.Schedule
c.Weekly schedule
Date/Time
Day:
Sunday
Date:
06/12/15
Time:
07:25
Daily saving time
Enable:
Transition time:
60min
Start: Last
SUN
in MARCH
at
2:00
End: Last
SUN
in OCTOBER
at
3:00
User menu
2/8
On/Off
Programming
Heating
Programming
2/4
a.Date/time
b.Schedule
c.Weekly schedule
Heat pump schedule
Enable:
Day:
MONDAY
Copy to:
MONDAY
NO
1: 04:00
ON
2: 06:00
ON
3: 10:00
ON
4: 04:00
OFF
Holiday schedule
Enable:
State:
Swiched Off
Sp. Season
Start
Stop
1.Month/Day 00/00
00/00
2.Month/Day 00/00
00/00
3.Month/Day 00/00
00/00
User menu
2/8
On/Off
Programming
Heating
Programming
3/4
a.Date/time
b.Schedule
c.Weekly schedule
Night-time
Enable
Start:
23:00
End:
7:00
Compressor:
50.0%
Air Unit:
40.0%
XXXXXX
Enable:
Day:
MONDAY
Copy to:
MONDAY
NO
1: 04:00
ON
45ºC
2: 06:00
ON
55ºC
3: 10:00
ON
40ºC
4: 04:00
OFF
ºC
Holiday schedule
Enable:
State:
Swiched Off
Sp. Season
Start
Stop
1.Month/Day 00/00
00/00
2.Month/Day 00/00
00/00
3.Month/Day 00/00
00/00
Summary of Contents for NETZERO BW B B