S53-053 Panther
11 of 53
Press an emergency
switch to deactivate
the machine.
Pull out the switch to release
Rotate the switch clockwise to
release
Fig. 53 DS, item 20
Fig. 53 DS, item 20
After pressing an emergency switch, release as described above and start up the system as during
a normal start-up.
Main power switch
The main power switch is located on the control cabinet.
(Fig. 53 DS, item 1)
Main circuit breaker
The crawler is equipped with a main circuit breaker inside the work cabin.
The main circuit breaker is located on the front control panel, at the bottom of the
control cabinet (Fig. 53 DT, item 3).
The main circuit breaker switch must be in the
"
ON
"
position when operating
the crawler (the key is locked in).
Set the main circuit breaker switch to the “OFF” position and take out the key
when not operating the crawler over a longer period of time.
When servicing the powerpack or electrical installation the main circuit breaker
key must be removed and a padlock must be locked in the main circuit breaker
to prevent another key to be placed.