GLX-RSS-2-300 WL User Manual
44
GLX-RSS-2-300 WL Non-Contact Flow Meter
Name
Command
Response
Details
Send Data
aD0!
a<val0><CR><LF>
a<val0><CRC><CR><LF>
val0
→
a±f±f+d+d+d <cl><rf>
±f - discharge in defined units
±f - average velocity in defined
units
+d - average SNR in dBm
+d - angle in dBm
+d - signal quality
(3->unacceptable, 2 ->low,
1->good, 0->excellent )
val1
→
a±f±f±d±f <cl><rf>
±f - relative level depending on
sensor height in defined units
±f - distance from sensor to water
in defined units
±d - level SNR in dBm
±f - standard deviation of water
level in mm
val2
→
a±d+d+d <cl><rf>
±d – internal device temperature
in °C
+d – measured tilt angle
of device in x direction
+d – measured tilt angle
of device in y direction
aD1!
a<val1><CR><LF>
a<val1><CRC><CR><LF>
Additional Data
aD1! .. aD9!
a0<CR><LF>
a0<CRC><CR><LF>
Concurrent
Measurement
Send Data
aC!/aCC!
ammm12<CR><LF>
aD0!
a<val0><CR><LF>
a<val0><CRC><CR><LF>
aD1!
a<val1><CR><LF>
a<val1><CRC><CR><LF>
aD2!
a<val2><CR><LF>
a<val2><CRC><CR><LF>
Additional Data
aD3! ... aD9!
a<CR><LF> a<CRC><CR><LF>
No values are returned for
additional data.
Continuous
Measurement
aR0! ... aR9!
a<CR><LF>
a<CRC><CR><LF>
The continuous mode is not sup
-
ported
Get Velocity/
Discharge Unit
aXGWUN!
a+d<CR><LF>
+d – measurement unit for veloc
-
ity 0 – mm/s, 1 – m/s, 2 – mph, 3
– km/h, 4 – fps, 5 – fpm
Set Velocity/
Discharge Unit
d! a+d<CR><LF>
+d – measurement unit for veloc
-
ity 0 – mm/s, 1 – m/s, 2 – mph, 3
– km/h, 4 – fps, 5 – fpm
Get Velocity
Average Factor
aXGWAV!
a+d<CR><LF>
+d – averaging velocity length
1-512
Set Velocity
Average Factor
d! a+d<CR><LF>
+d – averaging velocity length
1-512
Get Direction Filter
Factor
aXGDFT!
a+d<CR><LF>
+d – direction filter for velocity
0 – both, 1 – incoming, 2 – outgo
-
ing
Set Direction Filter
Factor
d!
a+d<CR><LF>
+d – direction filter for velocity
0 – both, 1 – incoming, 2 – outgo
-
ing
Summary of Contents for GLX-RSS-2-300 WL
Page 71: ...2022 ...