background image

SPRINT 05 SW

ENGLISH

Guide for the installer

Page 12

11. FUNCTION L

OGIC

S

Automatic logic

Gate status

Pulses

Open 

A

Open B

Stop

Safety devices at closing. 

Safety devices at closing and 

opening

Closed

Opens and re-closes the gate 

after the pause time

Opens for 8 seconds and closes 

after the pause time

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

Open in pause

Immediately recloses the gate 

Immediately recloses 

Stops operation 

(2)

Recharges

 pause time 

(3)

Recharges pause time

 

(3)

At closing

Stops or reverses gate 

 

movement 

(1)

No ef

fect 

Stops operation 

(2)

Reverses gate movement

Stops operation and reverses  motion when the safety switch 

is released

At opening

Stops or reverses gate 

 

movement 

(1)

Reverses gate movement

Stops operation 

(2)

No ef

fect 

Stops operation and resumes 

when released

Manual logic

Gate status

Pulses

Open 

A

Open B

Stop

Safety devices at closing. 

Safety devices at closing and 

opening

Closed

Opens the gate 

Opens the gate for 8 seconds

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

Open in pause

Closes the gate 

Closes the gate 

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

If enabled, disables the OPEN 

commands

At closing

Stops or reverses gate 

 

movement 

(1)

No ef

fect 

Stops operation

Reverses gate movement

Stops operation and reverses  motion when the safety switch 

is released

At opening

Stops or reverses gate 

 

movement 

(1)

Reverses gate movement

Stops operation

No ef

fect 

Stops operation and resumes 

when released

(1) The behaviour of the Open 

A push-button is set using dip-switch 4, see paragraph 7.

(2) The Stop pulse blocks operation of the gate and disables all the selected automatic functions. 

An Open 

A pulse is required to resume the memorised cycle.

(3) If when the set pause time elapses the safety switch is engaged, when it is released the unit will resume the time count of the programmed pause time.

Summary of Contents for SPRINT 05 SW

Page 1: ...SPRINT 05 SW ISTRUZIONI PER L USO INSTRUCTIONS FOR USE INSTRUCTIONS POUR L USAGER INSTRUCCIONES PARA EL USO GEBRAUCHSANLEITUNG GIDS VOOR DE GEBRUIKER...

Page 2: ...ed with an intrinsic anti crushing safety device consisting of a torque control Nevertheless its tripping threshold must be checked as specified in the Standards indicated at point 10 16 The safety de...

Page 3: ...n zu berpr fen 16 Die Sicherheitsvorrichtungen Norm EN 12978 erm glichen den Schutz eventueller Gefahrenbereiche vor mechanischen Bewegungsrisiken wie zum Beispiel Quetschungen Mitschleifen oder Schni...

Page 4: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 1...

Page 5: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 2 Fig 3 Fig 2...

Page 6: ...requirements of the following EEC directives 2006 95 EC Low Voltage directive 2004 108 EC Electromagnetic Compatibility directive Additional information This product underwent a test in a typical uni...

Page 7: ...lose time 120 sec Pause time Four pre set levels Motor power Adjustable using a trimmer Terminal board inputs Open A Open B Stop Limit switch when opening Limit switch when closing Photocells Power Te...

Page 8: ...mally closed contact To these terminals connect any safety device push button key switch etc that must stop gate movement by disabling all automatic functions The gate should resume the memorised cycl...

Page 9: ...E OPERATING PARAMETERS All the programmable functions of the board are set using dip switch DP1 see Fig 1 The different options are listed in the diagram below OPERATING LOGIC Manual logic Automatic l...

Page 10: ...sted using dip switches 7 8 see paragraph 7 Important Use of the encoder does not substitute the limit switches which are mandatory 9 ADJUSTING THE MOTOR POWER The motor power can be adjusted in two w...

Page 11: ...en B Stop Safety devices at closing Safety devices at closing and opening Closed Opens the gate Opens the gate for 8 seconds If enabled disables the OPEN commands If enabled disables the OPEN commands...

Page 12: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 37...

Page 13: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 38...

Page 14: ...momento y sin comprometerse a poner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car ct...

Reviews: