1. GENERAL CHARACTERISTICS
We thank you for having chosen one of our products. GENIUS is certain that from it you will obtain all the performance you require. All
our products are the result of years of experience in the field of automated systems, with the added advantage of being part of one of the
sector’s world leading groups.
The
SPRINT 05 SW
control unit has been designed to control sliding operators with a maximum power of 600W.
The SW models are able to automatically recognise the input voltage with values that range from 95 V~ to 260 V~ (50 / 60 Hz). This
makes it possible to obtain constant output of both the motor and accessories, and therefore extremely smooth operation of the gear train
regardless of any possible sudden changes in voltage that may occur throughout the day.
Thanks to the active and passive safety controls, if correctly installed, it guarantees installation compliant with the safety regulations in
force. The fact that an encoder can also be managed makes it possible to further increase the level of safety.
The extreme simplicity in programming the main functions greatly reduces installation time.
Thanks to the 5 built-in LEDs, it is able to provide the state of the safety devices and limit switches at any given moment.
2. TECHNICAL SPECIFICATIONS
Power voltage
230V~ 50Hz / 115V~ 60Hz
Absorbed power
15 W
Max. load of motor
600 W
Max. load of accessories
500 mA
Operating ambient temperature
-20°C +55°C
Safety fuses
1
Operating logics
Automatic, Manual
Open /Close time
120 sec.
Pause time
Four pre-set levels
Motor power
Adjustable using a trimmer
Terminal board inputs
Open A, Open B, Stop, Limit switch when opening, Limit switch when closing, Photocells,
Power
Terminal board outputs
24 Vdc accessories power, Flashing lamp, Motor, Earthing
Rapid connector
Connector for 5-pin receivers, Encoder, Limit switch, Capacitor
Programmable functions
Operating logic, Pause time, Clutch sensitivity, Operation with encoder,
Safety logic, Condo function
Dimensions
145 x 105
3. BOARD LAY-OUT (Fig.1)
CN1
Encoder connector
DP1
Parameter setting dip-switch
CN2
Low-voltage terminal board
F1
Power/Motor fuses 3.15A T (5x20)
CN3
High- voltage terminal board
ALIM
Network power present LED
CN4
Receiver connector
FSW
FSW input state LED
CN5
Limit switch connector
STOP
STOP input state LED
CN6
Capacitor connector
FCA
FCA input state LED
TR1
Motor power adjustment trimmer
FCC
FCC input state LED
4. PREPARATIONS
For safety reasons, it is important for people to carefully follow all the warnings and instructions contained in this booklet.
Incorrect installation or incorrect use of the product can cause serious harm to people.
• Ensure that upstream from the system there is a suitable differential switch, as provided for in current safety regulations, and fit an
omnipolar magnetothermic switch on the power grid.
•
Check for the presence of an adequate earthing system.
• For cable installation use adequate rigid and/or flexible tubes.
•
Always separate the power cables from the low-voltage control cables. To avoid any interference, we recommend using separate sheathing.
5. CONNECTIONS AND OPERATION
5.1. CONNECTOR CN1
This connector is for use with an encoder. For encoder operation, refer to paragraph 8.
5.2. TERMINAL BOARD CN2 (Fig. 2)
Summary of Contents for SPRINT 05 SW
Page 4: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 1 Fig 1...
Page 5: ...SPRINT 05 SW Immagini Images Images Im genes Bilder Afbeeldingen Pag 2 Fig 2 Fig 3 Fig 2...
Page 12: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 37...
Page 13: ...SPRINT 05 SW NOTE NOTES NOTE NOTAS ANMERKUNG OPMERKINGEN Pagina 38...