AUTOMATION SYSTEMS ROLLER
The
ROLLER
automation system for swing gates is a geared motor. It is
designed for underground installation and therefore does not alter the
appearance of the leaf.
The foundation box of the automation system comes ready to take an
operator.
The
ROLLER
electromechanical operator is irreversible, so it ensures a mecha-
nical stop and eliminates the need to install an electric lock.
The ROLLER automated systems were designed and manufactured to
control access of vehicles. Avoid any other use whatever.
1. DESCRIPTION AND TECHNICAL CHARACTERISTICS
햲
Foundation box
햹
Pinion
햳
Bores for fastening boxcover
햺
Bore for power supply cable
pipe
햴
operator
햻
Bore for drain pipe
햵
Support bracket for gate
햽
Fastening screws for operator
햶
Locking bracket
햾
Lubrication bore
햷
Release device with key
햿
Boxcover
햸
Crank and connecting rod
assembly
헀
Plug of closing
Fig. 1
Model
Roller
Lento
Roller
230V
Roller
115V
Roller 24V
Power supply (Vac) (Vdc)
230
115
24
Power (W)
300
380
600
70
Current (A)
1.3
1.7
5.3
3
Thermal protection (°C)
140
/
Capacitor (µF)
12.5
30
/
Max torque (Nm)
250
330
300
Angular velocity (°/sec)
4
6
7
6
Max. leaf (m)
3.5 (110°) - 3 (180°) - 2 (140°)
Leaf opening angle (°)
110 (140 and 180 with kit)
Use type and frequency
S3 - 30%
100%
Minimum indicative hourly
cycles
20 (110° e
180°)
36 (140°)
30 (110° e 180°)
50 (140°)
100 (110°
e 180°)
170 (140°)
Operating ambient tempera-
ture (°C)
-20 ÷ +55
Operator weight (Kg)
26.5
Protection class
IP67
Operator dimensions (mm)
360 x 150 x 140
Box dimensions
See figura 2
2. DIMENSIONS
Fig. 2
3. MAXIMUM USE CURVE
The curve makes it possible to
establish maximum work time (T)
according to use frequency (F).
With reference to IEC 34-1 stan-
dard, the ROLLER gearmotor ope-
rating at S3 service, can function
at a use frequency of 30%.
To ensure efficient operation,
operate in the work range below
the curve.
The curve is obtained at
a temperature of 20°C.
Exposure to the direct
sun rays can reduce use
frequency down to 20%.
C
ALCULATION
OF
USE
FREQUENCY
The percentage of effective work time (o closing) compared to
total time of cycle (o c pause times).
Calculation formula:
Ta + Tc
% F = ––––––––––––––––––– X 100
Ta + Tc + Tp + Ti
where:
Ta = opening time
Tc = closing time
Tp = pause time
Ti = time of interval between two complete cycles
4. ELECTRIC EQUIPMENT (STANDARD SYSTEM)
햲
Operators ROLLER (require 2 junction boxes)
햳
Photocells
햴
Control unit
햵
Pushbutton
햶
Flashing light
Fig. 3
To lay electrical cables, use adequate rigid and/or flexible tubes.
Always separate low voltage accessories from those operating at
230/115 V~. To avoid any interference, always use separate shea-
ths.
Use frequency graph
Use frequency graph