background image

7

ENGLISH

FALCON M AUTOMATED SYSTEM

These instructions apply to the following models:

FALCON 14 M - FALCON 14 MC - FALCON 20 M- FALCON 20 MC - FALCON 

15 M - FALCON 15 MC - FALCON 20 M 3PH

The 

FALCON

 gearmotor for sliding gates is an electro-mechanical operator 

which transmits drive to the sliding leaf by a rack and pinion or by a chain 

suitably coupled to the gate.

The  non-reversing  system  guarantees  mechanical  locking  of  the  gate 

when the motor is not operating and, therefore, there is no need to install 

any lock.

The gearmotor does not have a mechanical clutch and, therefore, 

requires a control unit with an adjustable electronic clutch which 

guarantees the necessary anti-crushing safety.

A handy manual release with a customised key makes the gate manoeu-

vrable in case of a power cut or trouble.

In the “

C

” version gearmotors, the electronic control unit is housed inside 

the operator.

 The 

FALCON

 gearmotor was designed and built for controlling vehicle 

access. Do not use in any different way.

1. DESCRIPTION AND TECHNICAL SPECIFICATIONS

MODEL

5 M

5 MC

8 M

8 MC

424 M

424 MC

Power supply (+6% -10%)

230 V~

50 Hz

115 V~

60 Hz

230 V~

50 Hz

115 V~

60 Hz

230 V~

50 Hz

115 V~

60 Hz

Absorbed power (W)

350

500

600

70

Absorbed current (A)

1.5

3

2.2

5.2

3

Thrust capacitor (µF)

10

30

12.5

50

/

Thrust on pinion (daN)

45

65

40

Torque (Nm)

18

24

13.5

Temperature protection (°C)

140

/

Max leaf weight (Kg)

500

800

400

Type of pinion gear

Z 16 module 4

Gate speed (m/min)

12

14

12

14

12

Max. gate length (m)

15

Type of travel-limit device

Magnetic

Type of clutch

Electronic torque control

(See control unit)

Use frequency (see graph)

S3 - 30%

S3 - 40%

100%

Operating ambient tempe-

rature (°C)

-20 ÷ +55

Weight of gearmotor (Kg)

9

(10 Falcon 

5MC)

10

(11 Falcon 

8MC)

7.5

(8.5 Falcon 

424MC)

Protection class

IP 44

Operator dimensions 

See fig. 2

2. DIMENSIONS

3. MAXIMUM USE CURVE

The  curve  makes  it  possible  to 

establish maximum work time (T) 

according to use frequency (F).

With  reference  to  standard  IEC 

34-1, the 

FALCON

 gearmotor, with 

service  type  S3,  can  operate  at 

use frequency of 40%.

To  ensure  efficient  operation, 

operate in the work range under 

the curve.

   Important:  The  curve  is 

obtained at a temperature 

of  20°C.  Exposure  to  the 

direct sun rays can reduce 

use  frequency  down  to 

20%.

Calculation of use frequency

The percentage of effective work time (o closing) compared to 

total time of cycle (o c pause times).

Calculation formula:

Ta + Tc

   

 

 

% F = 

X 100

Ta + Tc + Tp + Ti

where:

Ta  =  

opening time

Tc  =  

closing time

Tp  =  

pause time

Ti   =  

interval time between one complete cycle and another

4. ELECTRONIC DEVICES (standard system)

Covering housing

Gearmotor

Release knob with key

Pinion

Sensor cover plug

Magnetic sensor

Securing plate with nuts and wall anchors

Magnetic counter-plates

Tube wrench

Toroidal transformer (for 

Falcon 424 C

 only)

Encoder (for 

Falcon 424 C

 only)

Control  unit  with  support  (for  versions  “

C

” 

only)

Pos. Description 

Connection cable

Gearmotor

3x2.5 mm

(230/115V~)

Photocell transmitter 

2x0.5 mm

(TX)

Photocell receiver

4x0.5 mm

(RX)

Key-operated selector switch 

2x0.5 mm

2

Flashing light

2x1.5 mm

2

External receiver (optional)

3x0.5 mm

2

Fig. 1

Fig. 2

Fig. 3

Summary of Contents for Falcon 5M

Page 1: ...FALCON 5M 8M 424M FALCON 5M 8M 424M...

Page 2: ...17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 The automated system is supplied with an intrinsic anti crushing safety device con sisting of a torque control Nevertheless its tripping...

Page 3: ...ent amendment 92 31 EEC and 93 68 EEC Furthermore the manufacturer declares that the machinery must not be put into service until the machine into which it will be incorporated or of which it will bec...

Page 4: ...Max gate length m 15 Type of travel limit device Magnetic Type of clutch Electronic torque control See control unit Use frequency see graph S3 30 S3 40 100 Operating ambient tempe rature C 20 55 Weig...

Page 5: ...he cables through the slot on the operator s reduction element Adjust the height of the gearmotor and the distance from the gate referring to dimensions in Fig 10 This operation is necessary to secure...

Page 6: ...a 230V power supply and type T3 15A 250V 5x20 for a 115V power supply 6 2 POSITIONING THE TRAVEL LIMIT ELEMENTS To correctly position the travel limit magnets the control unit must first be installed...

Page 7: ...as shown in Fig 22 Ref 2 Turn the release system clockwise by about 180 as shown in Fig 22 Ref 3 Open and close the gate manually 9 RESTORING NORMAL OPERATION MODE To prevent an involuntary pulse from...

Page 8: ...chriften zu berpr fen Die Sicherheitsvorrichtungen Norm EN 12978 erm glichen den Schutz eventueller Gefahrenbereiche vor mechanischen Bewegungsrisiken wie zum Beispiel Quet schungen Mitschleifen oder...

Page 9: ...l derecho dejando inmutadas las caracter sticas esenciales de los aparatos de aportar en cualquier momento y sin comprometerse a poner al d a la presente publicaci n todas las modificaciones que consi...

Reviews: