7
ENGLISH
FALCON M AUTOMATED SYSTEM
These instructions apply to the following models:
FALCON 14 M - FALCON 14 MC - FALCON 20 M- FALCON 20 MC - FALCON
15 M - FALCON 15 MC - FALCON 20 M 3PH
The
FALCON
gearmotor for sliding gates is an electro-mechanical operator
which transmits drive to the sliding leaf by a rack and pinion or by a chain
suitably coupled to the gate.
The non-reversing system guarantees mechanical locking of the gate
when the motor is not operating and, therefore, there is no need to install
any lock.
The gearmotor does not have a mechanical clutch and, therefore,
requires a control unit with an adjustable electronic clutch which
guarantees the necessary anti-crushing safety.
A handy manual release with a customised key makes the gate manoeu-
vrable in case of a power cut or trouble.
In the “
C
” version gearmotors, the electronic control unit is housed inside
the operator.
The
FALCON
gearmotor was designed and built for controlling vehicle
access. Do not use in any different way.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
MODEL
5 M
5 MC
8 M
8 MC
424 M
424 MC
Power supply (+6% -10%)
230 V~
50 Hz
115 V~
60 Hz
230 V~
50 Hz
115 V~
60 Hz
230 V~
50 Hz
115 V~
60 Hz
Absorbed power (W)
350
500
600
70
Absorbed current (A)
1.5
3
2.2
5.2
3
Thrust capacitor (µF)
10
30
12.5
50
/
Thrust on pinion (daN)
45
65
40
Torque (Nm)
18
24
13.5
Temperature protection (°C)
140
/
Max leaf weight (Kg)
500
800
400
Type of pinion gear
Z 16 module 4
Gate speed (m/min)
12
14
12
14
12
Max. gate length (m)
15
Type of travel-limit device
Magnetic
Type of clutch
Electronic torque control
(See control unit)
Use frequency (see graph)
S3 - 30%
S3 - 40%
100%
Operating ambient tempe-
rature (°C)
-20 ÷ +55
Weight of gearmotor (Kg)
9
(10 Falcon
5MC)
10
(11 Falcon
8MC)
7.5
(8.5 Falcon
424MC)
Protection class
IP 44
Operator dimensions
See fig. 2
2. DIMENSIONS
3. MAXIMUM USE CURVE
The curve makes it possible to
establish maximum work time (T)
according to use frequency (F).
With reference to standard IEC
34-1, the
FALCON
gearmotor, with
service type S3, can operate at
use frequency of 40%.
To ensure efficient operation,
operate in the work range under
the curve.
Important: The curve is
obtained at a temperature
of 20°C. Exposure to the
direct sun rays can reduce
use frequency down to
20%.
Calculation of use frequency
The percentage of effective work time (o closing) compared to
total time of cycle (o c pause times).
Calculation formula:
Ta + Tc
% F =
X 100
Ta + Tc + Tp + Ti
where:
Ta =
opening time
Tc =
closing time
Tp =
pause time
Ti =
interval time between one complete cycle and another
4. ELECTRONIC DEVICES (standard system)
Covering housing
Gearmotor
Release knob with key
Pinion
Sensor cover plug
Magnetic sensor
Securing plate with nuts and wall anchors
Magnetic counter-plates
Tube wrench
Toroidal transformer (for
Falcon 424 C
only)
Encoder (for
Falcon 424 C
only)
Control unit with support (for versions “
C
”
only)
Pos. Description
Connection cable
Gearmotor
3x2.5 mm
2
(230/115V~)
Photocell transmitter
2x0.5 mm
2
(TX)
Photocell receiver
4x0.5 mm
2
(RX)
Key-operated selector switch
2x0.5 mm
2
Flashing light
2x1.5 mm
2
External receiver (optional)
3x0.5 mm
2
Fig. 1
Fig. 2
Fig. 3