Part No. 114047
Self-Propelled Servicing Platform
19
Operator's Manual
Second Edition • Fifth Printing
FUNCTION TESTS
Test Machine Functions
32 Press down the foot switch.
33 Activate each machine function control handle
or toggle switch.
Result: All boom/platform functions should
operate through a full cycle.
Note: Control the speed of boom functions by
adjusting the boom function speed controller. Drive
and steer functions are not affected by the boom
function speed controller.
Test the Steering
34 Press down the foot switch.
35 Depress the thumb rocker switch on top of the
drive control handle in the direction identified by
the blue triangle on the control panel.
Result: The steer wheels should turn in the
direction that the blue triangles point on the
drive chassis.
36 Depress the thumb rocker switch in the direction
identified by the yellow triangle on the control
panel.
Result: The steer wheels should turn in the
direction that the yellow triangles point on the
drive chassis.
At the Platform Controls
Test Emergency Stop
21 Push in the platform red Emergency Stop button
to the off position.
22 Activate each machine function control handle
or toggle switch.
Result: No functions should operate.
23 Pull out the red Emergency Stop button to the
on position.
Test the Horn
24 Push the horn button.
Result: The horn should sound.
Test the Beacon
25 Move the beacon toggle switch to the on
position.
Result: The beacon should flash.
26 Move the beacon toggle switch to the foot
switch activated on position. Do not step on the
foot switch.
Result: The beacon should not flash.
27 Press down the foot switch.
Result: The beacon should flash.
Test the Foot Switch
28 Push in the platform red Emergency Stop button
to the off position.
29 Pull out the red Emergency Stop button to
the on position but do not start the engine.
30 Press down the foot switch and attempt to start
the engine by moving the start toggle switch to
either side.
Result: The engine should not start.
31 Do not press down the foot switch and test each
machine function.
Result: The machine functions should not
operate.