18
Self-Propelled Servicing Platform
Part No. 114047
Operator's Manual
Second Edition • Fifth Printing
FUNCTION TESTS
14 Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The alarm should
sound while any function is operating.
Test the Tilt Sensor
15 Turn the key switch to platform control. Pull out
the platform red Emergency Stop button to the
on position.
16 Open the engine side
turntable cover and locate
the tilt sensor to the right of
the engine.
17 Press down one side of the
tilt sensor and hold for 5
seconds.
Result: The alarm, located
in the platform, should
sound.
Test Auxiliary Controls
18 Turn the key switch to ground control.
19 Pull out the red Emergency Stop button to the
on position.
20 Simultaneously hold the auxiliary
power switch on and activate
each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
4 Start the engine. See Operating Instructions
section.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine should turn off and all
functions should not operate.
6 Pull out the red Emergency Stop button to
the on position.
Test Thermometer
7 Start the engine.
8 Check the thermometer on the control panel.
Result: The temperature should rise.
9 Push in the red Emergency Stop button to turn
off the engine.
Test the Engine Lock-out Switch
10 Move the engine lock-out switch to the off
position.
11 Push the engine start button.
Result: The engine should not start.
12 Move the engine lock-out switch to the on
position.
Test the Machine Functions
13 Do not hold the function enable
switch to either side. Attempt to
activate each boom and platform
function toggle switch.
Result: All boom and platform functions should
not operate.
Summary of Contents for Z45/25J