September 2018
Service and Repair Manual
Control System
Part No. 1288652GT
S
®
-60 XC
™
• S
®
-65 XC
™
27
Screen or Menu
Item
Default
Deutz TD2011
Anti-Stall
Threshold
default = 2350 rpm
Drive Minimum
default = 50%
Range
default = 100 rpm
Hysteresis
default = 125 rpm
Screen or Menu
Item
Default
Perkins 404D
Anti-Stall
Threshold
default = 2350 rpm
Drive Minimum
default = 50%
Range
default = 125 rpm
Hysteresis
default = 100 rpm
Screen or Menu
Item
Default
Perkins 404F
Anti-Stall
Threshold
default = 2350 rpm
Drive Minimum
default = 50%
Range
default = 125 rpm
Hysteresis
default = 100 rpm
Screen or Menu
Item
Default
Ford MSG425
Anti-Stall
Threshold
default = 2375 rpm
Drive Minimum
default = 85%
Range
default = 125 rpm
Hysteresis
default = 170 rpm
Summary of Contents for S-65 XC CE
Page 87: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 77 ...
Page 89: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 79 ...
Page 97: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 87 ...
Page 151: ...September 2018 Service and Repair Manual 141 Electrical Schematic TCON ...
Page 154: ...Service and Repair Manual September 2018 144 Electrical Schematic PCON ...
Page 155: ...September 2018 Service and Repair Manual 145 Electrical Schematic Deutz 2 9L Models ...
Page 158: ...Service and Repair Manual September 2018 148 Electrical Schematic Deutz D2011 Models ...
Page 159: ...September 2018 Service and Repair Manual 149 Electrical Schematic Perkins 404F Models ...
Page 162: ...Service and Repair Manual September 2018 152 Electrical Schematic Perkins 404D Models ...
Page 163: ...September 2018 Service and Repair Manual 153 Electrical Schematic Ford MSG425 Models ...
Page 166: ...Service and Repair Manual September 2018 156 Electrical Schematic Generators ...
Page 169: ......