Service and Repair Manual
September 2018
Deutz D 2.9 L4 Engine Fault Codes
122
S
®
-60 XC
™
• S
®
-65 XC
™
Part No. 1288652GT
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523605 9
300
Timeout Error of
CAN-Receive-Frame TSC1AE;
Traction Control
523606 9
301
Timeout Error of
CAN-Receive-Frame TSC1AR;
Retarder
523612 12
387
Internal software error ECU;
injection cut off
523612 12
612
Internal ECU monitoring
detection reported error
523612 12
613
Internal ECU monitoring
detection reported error
523612 12
614
Internal ECU monitoring
detection reported error
523612 12
615
Internal ECU monitoring
detection reported error
523612 12
616
Internal ECU monitoring
detection reported error
523612 12
617
Internal ECU monitoring
detection reported error
523612 12
618
Internal ECU monitoring
detection reported error
523612 12
619
Internal ECU monitoring
detection reported error
523612 12
620
Internal ECU monitoring
detection reported error
523612 12
621
Internal ECU monitoring
detection reported error
523612 12
623
Internal ECU monitoring
detection reported error
523612 12
624
Internal ECU monitoring
detection reported error
523612 12
625
Internal ECU monitoring
detection reported error
523612 12
627
Internal ECU monitoring
detection reported error
523612 12
628
Internal ECU monitoring
detection reported error
SPN
FMI KWP Description
523612 12
637
Internal ECU monitoring
detection reported error
523612 12
1170 Internal software error ECU
523612 14
973
Softwarereset CPU SWReset_0
523612 14
974
Softwarereset CPU SWReset_1
523612 14
975
Softwarereset CPU SWReset_2
523613 0
856
Maximum positive deviation of
rail pressure exceeded
(RailMeUn0)
523613 0
857
Maximum positive deviation of
rail pressure in metering unit
exceeded (RailMeUn1)
523613 0
858
Railsystem leakage detected
(RailMeUn10)
523613 0
859
Maximum negative deviation of
rail pressure in metering unit
exceeded (RailMeUn2)
523613 0
860
Negative deviation of rail
pressure second stage
(RailMeUn22)
523613 0
862
Maximum rail pressure exceeded
(RailMeUn4)
523613 1
861
Minimum rail pressure exceeded
(RailMeUn3)
523613 2
864
Setpoint of metering unit in
overrun mode not plausible
523615 3
594
Metering unit (Fuel-System);
short circuit to battery highside
523615 3
596
Metering unit (Fuel-System);
short circuit to battery low side
523615 4
595
Metering unit (Fuel-System);
short circuit to ground high side
523615 4
597
Metering Unit (Fuel-System);
short circuit to ground low side
523615 5
592
Metering unit (Fuel-System);
open load
523615 12
593
Metering unit (Fuel-System);
powerstage over temperature
523619 2
488
Physical range check high for
exhaust gas temperature
upstrem (SCR-CAT)
523698 11
122
Shut off request from supervisory
monitoring function
Summary of Contents for S-65 XC CE
Page 87: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 77 ...
Page 89: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 79 ...
Page 97: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 87 ...
Page 151: ...September 2018 Service and Repair Manual 141 Electrical Schematic TCON ...
Page 154: ...Service and Repair Manual September 2018 144 Electrical Schematic PCON ...
Page 155: ...September 2018 Service and Repair Manual 145 Electrical Schematic Deutz 2 9L Models ...
Page 158: ...Service and Repair Manual September 2018 148 Electrical Schematic Deutz D2011 Models ...
Page 159: ...September 2018 Service and Repair Manual 149 Electrical Schematic Perkins 404F Models ...
Page 162: ...Service and Repair Manual September 2018 152 Electrical Schematic Perkins 404D Models ...
Page 163: ...September 2018 Service and Repair Manual 153 Electrical Schematic Ford MSG425 Models ...
Page 166: ...Service and Repair Manual September 2018 156 Electrical Schematic Generators ...
Page 169: ......