Service and Repair Manual
September 2018
Control System Fault Codes
104
S
®
-60 XC
™
• S
®
-65 XC
™
Part No. 1288652GT
ID
Component ID Name
Cause
Effect
Solution
42
Turntable
Rotate CW
Valve
12 Circuit
shorted to
V+
TCON detected
that C4TRL circuit
is shorted to 12 V.
Turntable
Rotate
functions will
not operate.
* With a voltmeter, measure Y24. Proper
resistance should be between 5 - 60 ohms.
Replace Y24 if resistance is outside of
those values.
* Verify wiring for C4TRL (WH, TCON
J3-12) and check for open or short circuits.
15 Circuit
shorted to
GND
TCON detected
that C4TRL circuit
is shorted to
GND.
43
Turntable
Rotate CCW
Valve
12 Circuit
shorted to
V+
TCON detected
that C5TRR
circuit is shorted
to 12 V.
Turntable
Rotate
functions will
not operate.
* With a voltmeter, measure Y23. Proper
resistance should be between 5 - 60 ohms.
Replace Y23 if resistance is outside of
those values.
* Verify wiring for C5TRR (WH/BK, TCON
J3-1) and check for open or short circuits.
15 Circuit
shorted to
GND
TCON detected
that C5TRR
circuit is shorted
to GND.
44
Drive Enable
Switch
19 Stuck ON at
power up.
Toggle switch
input was
detected as HIGH
at start-up.
Drive Enable
switch will
not operate,
possibly
preventing
drive while
the turntable
is rotated.
Verify with a voltmeter that the Drive
Enable Toggle Switch (TS15) is operating
properly.
* C143DEL (BL/RD, PCON J16-7) should
be 0 V with the switch OFF and 12 V with
the switch held in the ON position.
Cycle power to allow the machine to re-test
the fault.
45
Platform
Level
Up/Down
Switch
19 Stuck ON at
power up.
Toggle switch
input was
detected as HIGH
at start-up.
Platform
Level Up or
Down
functions
may not
operate,
depending
on which
direction the
switch fault
occurred.
Verify with a voltmeter that the Platform
Level Up/Down Toggle Switch (TS9) is
operating properly.
* C14PLU (OR, PCON J17-2) should be 0
V with the switch OFF and 12 V with the
switch held in the UP position.
* C15PLD (OR/BK, PCON J17-3) should
be 0 V with the switch OFF and 12 V with
the switch held in the DOWN position.
Cycle power to allow the machine to re-test
the fault.
ID
Component ID Name
Cause
Effect
Solution
46
Platform
Rotate CW
Valve
12 Circuit
shorted to
V+
PCON detected
that V17PRL
circuit is shorted
to 12 V.
Platform
Rotate CW
function will
not operate.
* With a voltmeter, measure Y70. Proper
resistance should be between 5 - 60 ohms.
Replace Y70 if resistance is outside of
those values.
* Verify wiring for V17PRL (GR, PCON
J12-5) and check for open or short circuits.
15 Circuit
shorted to
GND
PCON detected
that V17PRL
circuit is shorted
to GND.
47
Platform
Rotate CCW
Valve
12 Circuit
shorted to
V+
PCON detected
that V18PRR
circuit is shorted
to 12 V.
Platform
Rotate CCW
function will
not operate.
* With a voltmeter, measure Y71. Proper
resistance should be between 5 - 60 ohms.
Replace Y71 if resistance is outside of
those values.
* Verify wiring for V18PRR (GR/BK, PCON
J12-4) and check for open or short circuits.
15 Circuit
shorted to
PCON detected
that V18PRR
Summary of Contents for S-65 XC CE
Page 87: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 77 ...
Page 89: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 79 ...
Page 97: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 87 ...
Page 151: ...September 2018 Service and Repair Manual 141 Electrical Schematic TCON ...
Page 154: ...Service and Repair Manual September 2018 144 Electrical Schematic PCON ...
Page 155: ...September 2018 Service and Repair Manual 145 Electrical Schematic Deutz 2 9L Models ...
Page 158: ...Service and Repair Manual September 2018 148 Electrical Schematic Deutz D2011 Models ...
Page 159: ...September 2018 Service and Repair Manual 149 Electrical Schematic Perkins 404F Models ...
Page 162: ...Service and Repair Manual September 2018 152 Electrical Schematic Perkins 404D Models ...
Page 163: ...September 2018 Service and Repair Manual 153 Electrical Schematic Ford MSG425 Models ...
Page 166: ...Service and Repair Manual September 2018 156 Electrical Schematic Generators ...
Page 169: ......