Service and Repair Manual
Control System Fault Codes
Part No. 1288652GT
S
®
-60 XC
™
• S
®
-65 XC
™
109
ID
Component ID Name
Cause
Effect
Solution
voltmeter set to resistance verify that pins
3 and 4 on the harness connector
measure between 110 and 130 Ohms.
Check wiring and boom cable for open or
short circuits if resistance check fails.
* Replace PCON if necessary.
34 Incorrect
software
version
PCON software
revision does not
match the system
revision level.
Boom Up
and Extend
functions will
not operate.
Reprogram the machine with latest
software. Check
http://firmware.genielift.com/ for the latest
software version.
36 Secondary
processor
not
detected.
TCON has not
detected the
PCON secondary
processor on the
communications
bus.
Controls from
the platform
will not
operate.
Reprogram the machine with latest
software. Check
http://firmware.genielift.com/ for the latest
software version.
79
Display
Controller
(DISCON)
13 Not
detected
TCON has not
detected the
DISCON on the
communications
bus.
Controls from
the ground
will not
operate.
* Verify DISCON is operating by checking
that the display on the front is operating
properly.
* If there is no display, try to power up the
DISCON by setting the keyswitch to
Ground, pull out the ground ESTOP and
press the Ground Function Enable button.
The display should start.
* If there is still no display, check DISCON
power on J10 pins 2 (+) and 1 (-).
* If DISCON operates but fault persists,
check the CAN bus wiring. Disconnect
J10 and with a voltmeter set to resistance
verify that the resistance between pins
3 and 4 on the harness connector are
between 55 and 65 ohms. Check CAN
wiring if resistance check fails.
* Replace DISCON if required.
34 Incorrect
software
version
DISCON software
revision does not
match the system
revision level.
Boom Up
and Extend
functions will
not operate.
Reprogram the machine with latest
software. Check
http://firmware.genielift.com/ for the latest
software version.
ID
Component ID Name
Cause
Effect
Solution
80
Turntable
Controller
(TCON)
13 Not
detected
The DISCON has
not detected the
TCON on the
CAN bus.
Machine will
not be
functional.
* Verify TCON is receiving power. Check
for 12 V on J5-2 (+) and J5-1 (-).
* Verify TCON is receiving ESTOP signals.
With ground ESTOP pulled out and
keyswitch set to Ground, verify 12 V is
reaching TCON J5-9 and J5-12.
* Verify CAN bus is functional. Pull out
connector J5 from the TCON and with a
voltmeter set to resistance verify that pins
3 and 4 on the harness connector
measure between 55 and 65 Ohms.
Check wiring and boom cable for open or
Summary of Contents for S-65 XC CE
Page 87: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 77 ...
Page 89: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 79 ...
Page 97: ...September 2018 Service and Repair Manual Manifolds Part No 1288652GT S 60 XC S 65 XC 87 ...
Page 151: ...September 2018 Service and Repair Manual 141 Electrical Schematic TCON ...
Page 154: ...Service and Repair Manual September 2018 144 Electrical Schematic PCON ...
Page 155: ...September 2018 Service and Repair Manual 145 Electrical Schematic Deutz 2 9L Models ...
Page 158: ...Service and Repair Manual September 2018 148 Electrical Schematic Deutz D2011 Models ...
Page 159: ...September 2018 Service and Repair Manual 149 Electrical Schematic Perkins 404F Models ...
Page 162: ...Service and Repair Manual September 2018 152 Electrical Schematic Perkins 404D Models ...
Page 163: ...September 2018 Service and Repair Manual 153 Electrical Schematic Ford MSG425 Models ...
Page 166: ...Service and Repair Manual September 2018 156 Electrical Schematic Generators ...
Page 169: ......