User Manual
IP65 200m Analogue Wireless RF Data Transceiver
7
Outputs 1 & 2
Both outputs are volt free with normally open, normally closed contacts and are capable of
switching loads of up to 1A @ 30V. Under software control these outputs can be configured
to work in either momentary, toggle or timer mode. The electrical connections are as
follows:
Output 3 / Tamper Relay
Output 3 has volt free contacts and can switch up to 1A @ 30V. This output can be
configured to work as either a tamper circuit (energised normally closed) or a third channel
(Normally Open [NO]). Please refer to the programming section to configure this output.
The electrical connections are as follows:
Power Supplies
The RF200D works from a 10-14V DC (Max.) power supply. The RF200D is
also reverse polarity protected. If using a separate power supply to drive the inputs
please ensure the 0V connections are commoned together.
RS232 / RS485 Data Channel
The RF200D has a data channel with RS232 or RS485 supported. Serial baud rates from
2400 to 19200 are possible with none, odd or even parity. Supported protocols are:
Genlink, Pelco D & P and an open channel. The electrical connections for both the RS232
and RS485 are listed below:
Aerial Connector
A threaded M4 connector for mounting of the rubber duck aerial. Please ensure the aerial
has its supplied rubber washer fitted between the case and aerial, and that the aerial is
done up hand tight to create a waterproof seal. If the washer is not fitted or the aerial
is loose possible water damage may occur which is not covered under the product
guarantee.