background image

18

7.0 RF200D Antenna Installation Guidelines

To obtain the maximum transmission range make sure the antenna is mounted at least 
300mm from any solid structure. This is not so important for short transmission ranges 
< 100 meters. Using the site survey mode described on page 8 will help obtain the best 
signal strength.

Summary of Contents for RF200D

Page 1: ...User Manual Please read these instructions carefully before operating the unit and keep for further reference V2 IP65 200m Analogue Wireless RF Data Transceiver RF200D ...

Page 2: ... Input Channels 1 2 Set Input Mode 13 6 8 Input Channels 1 2 Internal Input To Output Pairing 13 6 9 Output Channels 1 2 Pairing 14 6 10 Output Channels 1 2 Operational Modes 14 6 11 Output Channels 1 2 Timer Periods 14 6 12 Output Channels 1 2 Relay Test 15 6 13 Tamper Output 3rd Channel Overview 15 6 14 Tamper Third Channel Pairing 15 6 15 Tamper Third Channel Local Tamper Switch 16 6 16 Tamper ...

Page 3: ...nd can be configured to work in three modes momentary toggle and timed outputs with intervals from 1 second to 30 minutes An option to pair its own input to output allows the RF200D to work as a timer as well as transmitting its status to other paired devices The third output can be switched between a tamper relay and a third channel In tamper mode the RF200D can monitor local and remote tamper sw...

Page 4: ...n 25KHz SSB Bandwidth 114KHz Others Case Size without Aerial and Grommet 115 x 65 x 40mm Overall Size with Aerial and Grommet 305 x 65 x 40mm Ingress Protection IP65 Temperature Range 20 to 55 C Relative Humidity 95 Non Condensing 1 1 Product Features Repeat mode 6 RF channels Site survey mode Easy pairing menu Encrypted protocol DC10 14V operation 433MHz licence free Signal strength meter 3 x vol...

Page 5: ...5 2 1 Hardware Layout 2 0 Hardware ...

Page 6: ...iver 6 2 2 Hardware Description Inputs 1 2 Listed below are the four modes of operation for Inputs 1 2 Mode 1 External 12V signal Positive Trigger Mode 2 External 12V signal Negative Trigger Mode 3 Self Sense Normally Open Modes 4 Self Sense Normally Closed ...

Page 7: ...he RF200D works from a 10 14V DC Max power supply The RF200D is also reverse polarity protected If using a separate power supply to drive the inputs please ensure the 0V connections are commoned together RS232 RS485 Data Channel The RF200D has a data channel with RS232 or RS485 supported Serial baud rates from 2400 to 19200 are possible with none odd or even parity Supported protocols are Genlink ...

Page 8: ... for 5 seconds It is only advisable to enter one unit into site survey mode at any particular time Channel 1 or 2 Input Test Holding down either switch 1 or 2 for half a second sends the corresponding channel ON signal Any receiving device paired to this channel will activate its corresponding outputs Again this is useful for a engineer to check a channel is working correctly Tamper Switch Holding...

Page 9: ...1 2 The input output LED s for channels 1 2 flash at half second intervals when a channel is active Channel 3 Tamper The status LED flashes at half second intervals providing the tamper fault is local if a remote tamper fault has been detected the status LED will pulse twice When using this output as a third channel the status LED will only flash at half second intervals when active Data Channel D...

Page 10: ...lease refer to the programming section Input Channels Analogue Updates When an RF200D transmits a status update it measures the input voltages and transmits this level as a digital value in 50mV steps The purpose of this feature is for remote data logging etc and has no affect on the inputs previously described Repeat Function An RF200D can repeat other RF200D s signals The repeating RF200D still ...

Page 11: ...w is an example to demonstrate how to pair a single input to an output The following pages in this manual describe the other configuration modes for pairing the remaining peripherals To pair an input to an output is as follows 1 Place both RF200D s in configuration mode 2 Select an output channel to pair first RF200D 3 Select an input channel you wish to pair from second RF200D 4 On the second RF2...

Page 12: ...e available and are listed below 1 Genlink protocol This protocol is used for outputting all paired devices radio transmissions over either RS232 or RS485 port It is also possible to control a paired RF200D s outputs via this protocol A typical use for this protocol is expander modules extra I O channels Reading of an RF200D s analogue input voltages status monitoring in software door access contr...

Page 13: ...outwards to send the pairing signal to another RF200D device The receiving device will flash its signal LED 6 to indicate the reception 6 7 Input Channels 1 2 Set Input Mode Four possible modes are available see Hardware Description and are listed 6 8 Input Channels 1 2 Internal Input To Output Pairing The RF200D has an option to pair its own input to its own output One good reason for doing this ...

Page 14: ...dy configured before entering configuration mode Press the Aux channel you wish to pair on the Pelco interface and the RF200D will learn its address and Aux channel 6 10 Output Channels 1 2 Operational Modes The RF200D outputs can operate in three modes Momentary Toggle or Timer 1 Momentary means if any paired input is triggered the relay output is switched on 2 Toggle mode causes its output to fl...

Page 15: ... from a remote RF200D will not switch the third channel into a tamper channel but it can be used as another tamper input When a remote input is being used on a tamper channel triggering the input switches off the tamper relay i e the signal is inverted This can be a useful feature if you wish to report back a remote tamper state from a bell box or PIR etc If none of the above have been enabled or ...

Page 16: ...hen enabled any missing status updates generate a tamper fault and flash the tamper LED twice 6 17 Tamper Third Channel Relay Test The RF200D has a build in relay test function When the tamper and signal LED s 5 6 are flashing pressing the right switch turns on the relay and signal LED 1 6 18 Status Update Period Enabling the status updates forces the RF200D to transmit its status at a given perio...

Page 17: ...w are the LED states for repeat mode pairing 6 20 RF Channel Selection The RF200D has 7 RF channels and defaults to channel 5 Below is a list of all the channel numbers and their corresponding frequencies 6 21 Restore Factory Settings This option resets the RF200D back to factory default and erases any previously paired devices When selected all the status LED s flash together To reset the RF200D ...

Page 18: ...the maximum transmission range make sure the antenna is mounted at least 300mm from any solid structure This is not so important for short transmission ranges 100 meters Using the site survey mode described on page 8 will help obtain the best signal strength ...

Page 19: ...Sales 44 0 1707 330541 Enquiries sales genieproducts co uk Website www genieproducts co uk ...