User Manual
IP65 200m Analogue Wireless RF Data Transceiver
14
6.9 Output Channels 1 & 2 - Pairing
In this mode the RF200D accepts a pairing signal from another RF200D. Only inputs can
be paired to an output unless the data channel has been configured for either the Pelco
or Genlink protocol. For each new paired device (up to 5 units per channel) the signal
LED’s 1-5 increment. Holding down the right switch for more than 3 seconds clears any
previously paired devices on the currently selected output.
To pair a Pelco Aux command to an output, ensure Pelco is already configured before
entering configuration mode. Press the Aux channel you wish to pair on the Pelco interface
and the RF200D will learn its address and Aux channel.
6.10 Output Channels 1 & 2 - Operational Modes
The RF200D outputs can operate in three modes, Momentary, Toggle or Timer.
1. Momentary means if any paired input is triggered the relay output is switched on.
2. Toggle mode causes its output to flip on detection of any positive going signal from a
paired device.
3. In timed mode any positive going signal from a paired device will either start the timer
or reset the timer period to the beginning.
6.11 Output Channels 1 & 2 - Timer Periods
The RF200D allows various time periods, per channel, from 1 second to 30 minutes. Listed
below are the various timer periods.