Page
D - 26
Document 57.0008.7200 - 05/2007
Handler with telescopic boom
GTH-3512
MAINTENANCE
■
Relays
Ref.
Circuit
K1
RELAY - HIGH BEAM
K2
RELAY - LOW BEAM
K3
RELAY - HORN
K4
RELAY - WORK LIGHTS
K5
RELAY - 1
st
and 2
nd
MECHANICAL SPEED
K6
RELAY - NOT USED
K7
RELAY - FORWARD SPEED
K8
RELAY - REVERSE SPEED
K9
RELAY - TRANSMISSION DISCONNECTED
K10
RELAY - TRANSMISSION DISCONNECTED
K11
RELAY - START-UP ENABLING COMMAND
K12
RELAY - NOT USED
K13
RELAY - NOT USED
K14
RELAY - OUTRIGGERS
K15
RELAY - NOT USED
K16
RELAY - NOT USED
K17
RELAY - NOT USED
K18
RELAY - OPTIONAL
K19
RELAY - BLOCKED FORKS
K20
RELAY - NOT USED
K21
RELAY - POWER SUPPLY ACTIVATION FROM
PLATFORM (only with man-platform)
K22
RELAY - NOT USED
K23
INTERMITTENCE
K24
MODULE - STOPPED SHAFT
K26
SAFETY RELAY - ATTACHMENT COUPLING
■
Engine compartment fuses and relays
Ref. Amp. Circuit
F2G
50
MAIN FUSE
F3G
50
FUSE - GLOW PLUGS
K01
RELAY - START-UP
K02
RELAY - GLOW PLUG LED
K03
RELAY - PRE-HEATING
K02
F2G
K01
F3G
K03
F22
F23
F24
F25
F26
F27
F16
F17
F18
F19
F20
F21
F13
F14
F15
F7
F8
F9
F10
F11
F12
F1
F2
F3
F4
F5
F6
K23
J3
J2
J1
K8
K2
K10
K7
K4
K9
K3
K7
K14
K21
K18
K19
K5
K11
K1
K24
K22
K6
K12
K13
K15
K16
K17
K20
K26
ATTENTION
•
Do not use fuses having a higher amperage
than that recommended, since they can
damage the electric system seriously.
•
If the fuse blows after a short time, look for the
fault source by checking the electric system.
•
Always keep some spare fuses for an
emergency.
•
Never try to repair or short blown fuses.
•
Make sure the contacts of fuses and fuse-
sockets ensure a good electric connection and
are not oxidised.