5 - 28
Genie GS-2046 and GS-2646 and GS-3246
Part No. 72972
REV A
Section 5 • Troubleshooting Flow Charts
June 2003
CHART 16
Continued from
page 26.
5V
Check for voltage at
terminal 3 of the voltage
regulator on U3.
0V
Replace U3.
Check for continuity in
the blue data (+) line
from pin D of the
platform controls quick
disconnect to terminal
B1 at U5.
no continuity
continuity
Replace the coil cord
assembly OR replace
the control cable from
the platform to U5.
Check for continuity in
the green data (-) line or
the yellow data (-) line
from pin E of the
platform controls quick
disconnect to terminal
C1 at U5.
continuity Consult the Genie
Industries Service
Department.
no continuity
Replace the coil cord
assembly OR replace
the control cable from
the platform to U5.
800-610-4101
ActionRental.com
Summary of Contents for GS-2046
Page 1: ...Service Manual Part No 72972 September 2006 Rev B2 800 610 4101 ActionRental com ...
Page 169: ...800 610 4101 ActionRental com ...
Page 173: ...800 610 4101 ActionRental com ...
Page 177: ...800 610 4101 ActionRental com ...
Page 181: ...800 610 4101 ActionRental com ...
Page 185: ...800 610 4101 ActionRental com ...
Page 189: ...800 610 4101 ActionRental com ...
Page 193: ...800 610 4101 ActionRental com ...
Page 197: ...800 610 4101 ActionRental com ...
Page 201: ...800 610 4101 ActionRental com ...
Page 205: ...800 610 4101 ActionRental com ...
Page 209: ...800 610 4101 ActionRental com ...
Page 213: ...800 610 4101 ActionRental com ...
Page 235: ...Service Manual GS 2046 GS 2646 GS 3246 Part No 72972 Rev B2 800 610 4101 ActionRental com ...