Section 5 • Troubleshooting Flow Charts
REV A
Chart 14
Machine
Drives At Full
Speed With
Platform
Raised
Be sure the circuit
breaker and fuse are
not tripped or blown.
Be sure the batteries
are fully charged and
properly connected.
light is
not on
light
is on
See Chart 13 OR
remove the obstruction
from the pothole guard
OR consult the Genie
Industries Service
Department.
Check limit switch LS7
and LS8 for correct
adjustment.
With the key switch
turned to platform
controls and both
Emergency Stop buttons
pulled out to the
ON
position and the platform
in the stowed position,
drive the machine in
either direction. Is the
error indicator light on at
the platform controls?
Check the controller
adjustments (See
Repair Section) OR
replace the platform
controls OR replace the
ECM U5 OR consult the
Genie Industries Service
Department.
Adjust LS7 or LS8 (See
Repair Section) OR
repair or replace limit
switch wire circuit.
good
bad
800-610-4101
ActionRental.com
Summary of Contents for GS-2046
Page 1: ...Service Manual Part No 72972 September 2006 Rev B2 800 610 4101 ActionRental com ...
Page 169: ...800 610 4101 ActionRental com ...
Page 173: ...800 610 4101 ActionRental com ...
Page 177: ...800 610 4101 ActionRental com ...
Page 181: ...800 610 4101 ActionRental com ...
Page 185: ...800 610 4101 ActionRental com ...
Page 189: ...800 610 4101 ActionRental com ...
Page 193: ...800 610 4101 ActionRental com ...
Page 197: ...800 610 4101 ActionRental com ...
Page 201: ...800 610 4101 ActionRental com ...
Page 205: ...800 610 4101 ActionRental com ...
Page 209: ...800 610 4101 ActionRental com ...
Page 213: ...800 610 4101 ActionRental com ...
Page 235: ...Service Manual GS 2046 GS 2646 GS 3246 Part No 72972 Rev B2 800 610 4101 ActionRental com ...