5 - 12
Genie GS-2046 and GS-2646 and GS-3246
Part No. 72972
REV A
Section 5 • Troubleshooting Flow Charts
June 2003
Chart 7
Platform Down
Function
Inoperative
Be sure all other
functions operate
normally.
Be sure the circuit
breaker and fuse are
not tripped or blown.
Be sure the batteries
are fully charged and
properly connected.
With the key switch
turned to platform
controls and both
Emergency Stop buttons
pulled out to the on
position and the platform
raised slightly,
From serial number
17408 to 21262:
press
and hold the lift function
enable button and
activate the controller in
the
DOWN
direction and
check to see if the error
indicator light is on.
After serial number
21262:
press the lift
function select button
and activate the
controller in the
DOWN
direction and check to
see if the error indicator
light is on.
light is
on
light is not on
Label and disconnect
the wires from the coil
on the platform lowering
valve (item D) at the
platform lift cylinder and
check the resistance
(See Repair Section).
0V
Repair open in the WH
B6-down coil wire from
the platform lowering
valve coil (item D) to the
ECM U5 OR repair open
in the brown ground wire
circuit from the coil to
the battery module tray
OR replace U5 OR
consult the Genie
Industries Service
Department.
20V or more
0 or
infinite
ohms
23 to 25 ohms
Replace platform
lowering valve coil
(item D).
Repair or replace the
platform lowering valve
cartridge (item D).
Are there mechanical
restrictions keeping the
platform from lowering?
With the platform raised
and the safety arm
removed, pull the
manual platform
lowering handle at the
ground controls.
platform does
not lower
platform
lowers
With the platform raised
and the safety arm
installed, connect the
leads of a volt meter to
the wires on the platform
lowering coil (item D) on
the cylinder without
removing the wires.
From serial number
17408 to 21262:
Press and hold the lift
function enable button
and activate the
controller in the
DOWN
direction and check the
voltage.
After serial number
21262:
Press the lift
function select button
and activate the
controller in the
DOWN
direction and check the
voltage.
Repair or replace the
platform lowering valve
cartridge (item D) OR
repair or replace the lift
cylinder OR replace the
orifice or orifice washer
(item E) OR consult the
Genie Industries Service
Department.
Remove mechanical
restrictions keeping the
platform from lowering.
yes
no
Replace the platform
controls OR replace the
ECM U5 OR consult the
Genie Industries Service
Department.
800-610-4101
ActionRental.com
Summary of Contents for GS-2046
Page 1: ...Service Manual Part No 72972 September 2006 Rev B2 800 610 4101 ActionRental com ...
Page 169: ...800 610 4101 ActionRental com ...
Page 173: ...800 610 4101 ActionRental com ...
Page 177: ...800 610 4101 ActionRental com ...
Page 181: ...800 610 4101 ActionRental com ...
Page 185: ...800 610 4101 ActionRental com ...
Page 189: ...800 610 4101 ActionRental com ...
Page 193: ...800 610 4101 ActionRental com ...
Page 197: ...800 610 4101 ActionRental com ...
Page 201: ...800 610 4101 ActionRental com ...
Page 205: ...800 610 4101 ActionRental com ...
Page 209: ...800 610 4101 ActionRental com ...
Page 213: ...800 610 4101 ActionRental com ...
Page 235: ...Service Manual GS 2046 GS 2646 GS 3246 Part No 72972 Rev B2 800 610 4101 ActionRental com ...