April 2017
Service and Repair Manual
Ground Controls
Part No. 1272217
GS-30 • GS-32 • GS-46 • GS-47
31
5 Read and record the IP address.
Note: The display wil only show the
IP address for 3 seconds. Press the
scroll up button to display the IP
address for another 3 seconds.
6 On a PC, laptop or mobile device, set up a
wireless network for the portable router.
Note: Refer to the Operating System's procedure
for connecting to a wireless network.
7 After establishing a new wireless network,
select the appropriate network your portable
wireless router.
Note: Refer to the Operating System's procedure
for connecting to a wireless network.
8 Launch a web browser such as Internet
Explorer ®, Chrome ® or Firefox ® on your
PC, laptop or mobile device. Type the IP
address from step 5 into the web browser
address bar and press enter.
Result: The following screen will be displayed.
9 Enter the following username and password
then select
OK
.
Username: smart.link
Password: SL1000
Note: The username and password are case
sensitive.
Result: The following screen will be displayed.
10 After using the Smart Link Service Tool web
site, push in the red Emergency Stop button
and disconnect the CAT5 cable from the
GCON.
11 Secure the diagnostic port cover using the
retaining fasteners removed in step 3. Do not
over tighten.
Note: Machines equipped with AGM batteries will
need to select the AGM battery type using the
GCON set parameters screen. Refer to the
Machine Setup
procedure in the Service and
Repair manual that is appropriate for your machine.
Tip over hazard. Updating the
SmartLink software may have
impacted the machines default
drive speeds. Tipping over the
machine will result in death or
serious injury.
Perform drive speed test. Refer
to the
Maintenance Manual
that
is appropriate for your machine.
12 Perform a function test. Refer to the
Operator's Manual on your machine.