Type "HXXX" Faults
Part No. 1272217
GS-30 • GS-32 • GS-46 • GS-47
171
Type "HXXX" Faults, continued
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
H106:
GS-2646AV
H106:COILFAULT
DECK EXTEND:BAT-
Short circuit of the platform extend circuit to
battery negative.
• Short circuit in PED harness.
• PED extend valve coil short circuit.
• GCON ECM.
All functions inhibited.
H107:
GS-2646AV
H107:COILFAULT
DECK EXTEND:OPEN
Open circuit in the platform extend circuit.
• Open circuit in PED harness.
• PED extend valve coil open circuit.
• GCON ECM.
All functions inhibited.
H108:
GS-2646AV
H108:COILFAULT
DECK EXTEND:BAT+
Short circuit of the platform extend circuit to
battery positive.
• Short circuit in PED harness.
• PED extend valve coil short circuit.
• GCON ECM.
All functions inhibited.
H109:
GS-2646AV
H109:COILFAULT
DECK RETRACT:BAT-
Short circuit of the platform retract circuit to
battery negative.
• Short circuit in PED harness.
• PED retract valve coil short circuit.
• GCON ECM.
All functions inhibited.
H110:
GS-2646AV
H110:COILFAULT
DECK RETRACT:OPEN
Open circuit in the platform retract circuit.
• Open circuit in PED harness.
• PED retract valve coil open circuit.
• GCON ECM.
All functions inhibited.
H111:
GS-2646AV
H111:COILFAULT
DECK RETRACT:BAT+
Short circuit of the platform retract circuit to
battery positive.
• Short circuit in PED harness.
• PED retract valve coil short circuit.
• GCON ECM.
All functions inhibited.
H114:
GS-2646AV
H114:COILFAULT
DECK ENABLE:BAT+
Short circuit of the platform enable circuit to
battery positive.
• Short circuit in PED harness.
• PED enable valve coil short circuit.
• GCON ECM.
All functions inhibited.
H115:
GS-2646AV
H115:COILFAULT
DECK ENABLE
Short circuit of the platform enable circuit.
• Short circuit in PED harness.
• GCON ECM.
All functions inhibited.