Service and Repair Manual
April 2017
Platform Controls
18
GS-30 • GS-32 • GS-46 • GS-47
Part No. 1272217
Operational Indicator Codes
These codes are generated by the electrical
system to indicate machine operating status.
During normal operation, a code will appear in the
platform controls LED readout if a condition such
as off-level, overload cutout, chassis mode
operation or pothole guard stuck occurs.
If the platform controls LED readout displays an
operational indicator code such as LL, the fault
condition must be repaired or removed before
resuming machine operation. Push in and pull out
the red Emergency Stop button to reset the
system.
Platform Controls LED Readout
Code Condition
LL
Off-level
OL
Platform Overload (CE and Australia)
CH
Chassis Mode Operation
PHS
Pothole Guard Stuck
nd
No Drive (option)
Ld
Lifting Disabled (GS-3232 only)
Note: The
Ld
Operation Indicator Code will appear
when the outriggers are not fully retracted, the
machine is not auto leveled, an outrigger has lost
contact with the ground or either level sensor
detects the machine is no longer level. When any
of the above scenarios occur, the lift function is
disabled.
The lift function will also be disabled while
extending or retracting the outriggers and during
the outrigger auto level procedure. While
performing the above operations, the
Ld
Operation
Indicator Code will appear.
Note: A code and a description of a code can also
be viewed at the ground controls LCD display.