Service and Repair Manual
April 2017
Type "FXXX" Faults
178
GS-30 • GS-32 • GS-46 • GS-47
Part No. 1272217
Type "FXXX" Faults, continued
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
F023:
GS-3232
F023:SENSORFAULT
RR RIGGER:BAT-
Short circuit of the Right Rear Outrigger
Sensor circuit to battery negative.
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F034:
GS30,
GS32,
GS46 &
GS47
F034:SENSORFAULT
OVLD:PLAT HEIGHT
Height Sensor settings are not calibrated
correctly.
• Height sensor needs calibration for stowed
height and maximum height settings.
• GCON or PCON ECM.
All functions inhibited.
F035:
GS30,
GS32,
GS46 &
GS47
F035:SENSORFAULT
OVLD RANGE:LOW
Height Sensor setting is lower than calibrated
stowed height.
• Height sensor not calibrated for stowed height
correctly.
• GCON or PCON ECM.
All functions inhibited.
F036:
GS30,
GS32,
GS46 &
GS47
F036:SENSORFAULT
OVLD RANGE:HI
Height Sensor setting is higher than
calibrated maximum height.
• Height sensor not calibrated for maximum height
correctly.
• GCON or PCON ECM.
All functions inhibited.
F072:
GS-2646AV
F072:SENSORFAULT
FUNCTION CUT B+
Function Cutout sensor B+ fault.
• Faulty extension deck limit switch.
• Faulty gate proximity switch.
• GCON ECM.
All functions inhibited.
F073:
GS-2646AV
F073:SENSORFAULT
DECK SENSOR B+
Power Deck sensor B+ fault.
• Short circuit in deck sensor input circuit.
• GCON ECM.
All functions inhibited.
F129
:
GS30,
GS32,
GS46 &
GS47
F129:TILT SENSOR FAULT
UTS mismatch fault. Two accelerometers
inside UTS mismatch.(universal tilt sensor)
• Faulty UTS.
All functions inhibited.